EVAFLEX

EVAFLEX is a NCh / SEC (Chile) cable designation: EVAFLEX = Cocesa brand for halogen-free (EVA or polyolefin) insulation, class 5 flexible copper; EVAFLEX = Evaflex: Cocesa halogen-free flexible single-core wire without sheath (printed H07Z1-K (AS)). 450/750 V. SEC certificate; IEC 60332-1 and 60332-3.

2 coding systems recognise this code

Standard, worked reading and related types

Worked reading of EVAFLEX:

  • EVAFLEX: EVAFLEX = Cocesa brand for halogen-free (EVA or polyolefin) insulation, class 5 flexible copper; EVAFLEX = Evaflex: Cocesa halogen-free flexible single-core wire without sheath (printed H07Z1-K (AS)). 450/750 V. SEC certificate; IEC 60332-1 and 60332-3

NCh / SEC (Chile)

SymbolMeaning
EVAFLEXCocesa brand for halogen-free (EVA or polyolefin) insulation, class 5 flexible copper
EVAFLEXEvaflex: Cocesa halogen-free flexible single-core wire without sheath (printed H07Z1-K (AS)). 450/750 V. SEC certificate; IEC 60332-1 and 60332-3

China (GB / JB/T / MT cable model codes)

SymbolMeaning
ELow Smoke Zero Halogen Compound
VPolyvinyl Chloride (PVC)
AAluminium Foil With Polyethylene Sheath
FChloroprene Rubber
LAluminium Conductor
ELow Smoke Zero Halogen Compound
XNatural Or Styrene-Butadiene Rubber

How to read a China (GB / JB/T / MT cable model codes) cable code

What is EVAFLEX cable?

EVAFLEX: Evaflex: Cocesa halogen-free flexible single-core wire without sheath (printed H07Z1-K (AS)). Rating: 450/750 V. Standard: SEC certificate; IEC 60332-1 and 60332-3.

Documents and pages the readings were taken from

NCh / SEC (Chile): how to read the cable type names

Fire behaviour (EU CPR)

  • Halogen-free compound (EVAFLEX). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with EVAFLEX

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More NCh / SEC (Chile) designations

EVAFLEX