AR2V
AR2V is a UTE (France, NF C 30-202 traditional system) cable designation: A = Aluminium Conductor; R = Cross-Linked Polyethylene (XLPE); 2 = Thick (Reinforced) Sheath; V = Polyvinyl Chloride (PVC).
2 coding systems recognise this code
UTE (France, NF C 30-202 traditional system)
| Symbol | Meaning |
|---|---|
A | Aluminium Conductor |
R | Cross-Linked Polyethylene (XLPE) |
2 | Thick (Reinforced) Sheath |
V | Polyvinyl Chloride (PVC) |
How to read a UTE (France, NF C 30-202 traditional system) cable code
CEI-UNEL 35011 (Italy)
| Symbol | Meaning |
|---|---|
A | Aluminium Conductor |
R2 | Polyvinylchloride (PVC) |
V | Impregnated Glass Tape |
How to read a UTE (France, NF C 30-202 traditional system) cable code
A UTE (France, NF C 30-202 traditional system) designation (France) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 30 symbols for this system.
What does A mean in a UTE (France, NF C 30-202 traditional system) cable code? A means Aluminium Conductor.
What does R mean in a UTE (France, NF C 30-202 traditional system) cable code? R means Cross-Linked Polyethylene (XLPE).
What does 2 mean in a UTE (France, NF C 30-202 traditional system) cable code? 2 means Thick (Reinforced) Sheath.
What does V mean in a UTE (France, NF C 30-202 traditional system) cable code? V means Polyvinyl Chloride (PVC).
Fire behaviour (EU CPR)
PVC sheath (V).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with AR2V
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.
Related cables
More UTE (France, NF C 30-202 traditional system) designations