A/I-DQ(ZN)BH

A/I-DQ(ZN)BH is a DIN VDE 0888 (optical fibre) cable designation: A/I = Universal cable, indoor and outdoor; D = Bundle core (loose tube holding several fibres); Q = Swelling tape / fleece: longitudinal water tightness; (ZN) = Non-metallic strain-relief elements (glass or aramid yarn); B = Armouring (glass yarn: non-metallic rodent protection); H = Halogen-free (LSZH) sheath.

1 coding system recognises this code

DIN VDE 0888 (optical fibre)

SymbolMeaning
A/IUniversal cable, indoor and outdoor
DBundle core (loose tube holding several fibres)
QSwelling tape / fleece: longitudinal water tightness
(ZN)Non-metallic strain-relief elements (glass or aramid yarn)
BArmouring (glass yarn: non-metallic rodent protection)
HHalogen-free (LSZH) sheath

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

A/I-DQ(ZN)BH as the cable designer builds it, A/I-DQ(ZN)BH 1x12E9/125

Overall diameter 6.5 mm, 50 kg/km. An optical fibre cable has no conductor and no voltage: every size is its maker's, the layers no maker prints drawn at a typical value.

LayerMaterialThickness, mmOver the layer, mm
Loose tube (gel-filled, fibres inside)PBT0.422.8
Swelling tape (water block)Swelling0.333.5
Strength yarnsGlass yarn0.324.1
SheathHalogen-free (LSZH)1.26.5

A/I-DQ(ZN)BH on a drum

The smallest drum that passes every check, for 6.5 mm and about 50 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates within a few per cent of the cable makers' own tables: whole layers, wound diameter 1.05 × OD, 50 mm freeboard under the flange rim.

LengthDrum size (its makers)LayersGross weight
500 mKTG 5 (500 mm flange), plastic KTG drums (Europe), Bayka, KTG12 of 1828–29 kg
1,000 mKTG 6 (600 mm flange), plywood KTG drums (Europe), Bayka16 of 1857 kg

Barrel at least 20 × OD = 130 mm for a cable of this kind (Telecom, data and control cable): KTG table, the cable's datasheet wins. A load rating is the drum maker's own.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: A/I-DQ(ZN)BH

A/I-DQ(ZN)BH belongs to the family Fibre optic cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: Fibre optic cables