3GSEGCH
3GSEGCH is a HAR: HD 361 harmonised designation (CENELEC) cable designation: 3 = 300/300 V; G = Ethylene Vinylacetate (EVA); S = Silicone Rubber; E = Polyethylene (PE); G = Ethylene Vinylacetate (EVA); C = Concentric Copper Conductor; H = Flat Divisible (Separable) Cable Or Cord.
1 coding system recognises this code
Standard, worked reading and related types
Worked reading of 3GSEGCH:
3GSEGCH: 3 = 300/300 V; G = Ethylene Vinylacetate (EVA); S = Silicone Rubber; E = Polyethylene (PE); G = Ethylene Vinylacetate (EVA); C = Concentric Copper Conductor; H = Flat Divisible (Separable) Cable Or Cord
HAR: HD 361 harmonised designation (CENELEC)
| Symbol | Meaning |
|---|---|
3 | 300/300 V |
G | Ethylene Vinylacetate (EVA) |
S | Silicone Rubber |
E | Polyethylene (PE) |
G | Ethylene Vinylacetate (EVA) |
C | Concentric Copper Conductor |
H | Flat Divisible (Separable) Cable Or Cord |
How to read a HAR: HD 361 harmonised designation (CENELEC) cable code
How to read a HAR: HD 361 harmonised designation (CENELEC) cable code
A HAR: HD 361 harmonised designation (CENELEC) designation (Europe (CENELEC)) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 129 symbols for this system.
What does 3 mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? 3 means 300/300 V.
What does G mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? G means Ethylene Vinylacetate (EVA); or With Green-Yellow Protective Conductor (Multiplication Sign).
What does S mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? S means Special Standard (In The Style Of A Harmonised Design); or Silicone Rubber.
What does E mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? E means Polyethylene (PE).
What does C mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? C means Concentric Copper Conductor.
What does H mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? H means Harmonized Standard; or Flat Divisible (Separable) Cable Or Cord.
Fire behaviour (EU CPR)
PE sheath (E).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
FcaYMeKrvaslqwd, TKFFcaNA2XS(F)2Y, Waskönig+Walter
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with 3GSEGCH
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.
Related cables
More HAR: HD 361 harmonised designation (CENELEC) designations