247 NM 01
247 NM 01 is a IRAM / Mercosur (Argentina) cable designation: 247 NM = Mercosur standard NM 247 (IRAM NM 247 in Argentina, ABNT NBR NM 247 in Brazil); the ONC list gives the PNA-NM 247-3:2002 and 247-5:2002 editions; 01 = Single-core without sheath, rigid conductor, general use (ONC list wording); 247 NM 01 = Single-core PVC building wire without sheath, rigid conductor, general use. 450/750 V, PVC/A 70 C. IRAM NM 247-3 (Mercosur); PNA-NM 247-3:2002.
1 coding system recognises this code
Standard, worked reading and related types
Worked reading of 247 NM 01:
247 NM 01: 247 NM = Mercosur standard NM 247 (IRAM NM 247 in Argentina, ABNT NBR NM 247 in Brazil); the ONC list gives the PNA-NM 247-3:2002 and 247-5:2002 editions; 01 = Single-core without sheath, rigid conductor, general use (ONC list wording); 247 NM 01 = Single-core PVC building wire without sheath, rigid conductor, general use. 450/750 V, PVC/A 70 C. IRAM NM 247-3 (Mercosur); PNA-NM 247-3:2002
Related cable types: 247 NM 02 · 247 NM 42 · 247 NM 52 · 247 NM 53
IRAM / Mercosur (Argentina)
| Symbol | Meaning |
|---|---|
247 NM | Mercosur standard NM 247 (IRAM NM 247 in Argentina, ABNT NBR NM 247 in Brazil); the ONC list gives the PNA-NM 247-3:2002 and 247-5:2002 editions |
01 | Single-core without sheath, rigid conductor, general use (ONC list wording) |
247 NM 01 | Single-core PVC building wire without sheath, rigid conductor, general use. 450/750 V, PVC/A 70 C. IRAM NM 247-3 (Mercosur); PNA-NM 247-3:2002 |
What is 247 NM 01 cable?
247 NM 01: Single-core PVC building wire without sheath, rigid conductor, general use. Rating: 450/750 V, PVC/A 70 C. Standard: IRAM NM 247-3 (Mercosur); PNA-NM 247-3:2002.
450/750 V and 70 C are from the Superastic and Corfio sheets for the 02 family; the ONC list does not print the voltage next to type 01 (UNVERIFIED for 01). Rigid means class 1 or 2 (UNVERIFIED which).
Documents and pages the readings were taken from
IRAM / Mercosur (Argentina): how to read the cable type names
Fire behaviour (EU CPR)
PVC sheath (247 NM 01).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with 247 NM 01
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.