1-CXKE-R
1-CXKE-R is a HAR: HD 361 harmonised designation (CENELEC) cable designation: 1 = 100/100 V; C = Concentric Copper Conductor; X = Cross-Linked Polyethylene (XLPE); K = Zinc Sheath; E = Polyethylene (PE); R = Natural Or Synthetic Rubber (Today: Ethylene-Propylene Rubber Or Equivalent Elastomer, 60 °C).
1 coding system recognises this code
Standard, worked reading and related types
Worked reading of 1-CXKE-R:
1-CXKE-R: 1 = 100/100 V; C = Concentric Copper Conductor; X = Cross-Linked Polyethylene (XLPE); K = Zinc Sheath; E = Polyethylene (PE); R = Natural Or Synthetic Rubber (Today: Ethylene-Propylene Rubber Or Equivalent Elastomer, 60 °C)
Related cable types: 1-CXKH-R · 1-CHKE-R · 1-CXKH-V · 1-CHKE-V
HAR: HD 361 harmonised designation (CENELEC)
| Symbol | Meaning |
|---|---|
1 | 100/100 V |
C | Concentric Copper Conductor |
X | Cross-Linked Polyethylene (XLPE) |
K | Zinc Sheath |
E | Polyethylene (PE) |
R | Natural Or Synthetic Rubber (Today: Ethylene-Propylene Rubber Or Equivalent Elastomer, 60 °C) |
How to read a HAR: HD 361 harmonised designation (CENELEC) cable code
How to read a HAR: HD 361 harmonised designation (CENELEC) cable code
A HAR: HD 361 harmonised designation (CENELEC) designation (Europe (CENELEC)) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 129 symbols for this system.
What does 1 mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? 1 means 100/100 V; or 600/1000 V; or 1,0/1,0 kV a.c., 1,5 kV d.c. (EN 50618 PV cables; older EA 0038 PV cables: 1,8 kV d.c.).
What does C mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? C means Concentric Copper Conductor.
What does X mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? X means Cross-Linked Polyethylene (XLPE); or Without Green-Yellow Protective Conductor (Multiplication Sign); or Based On A Harmonised Design (Like S).
What does K mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? K means Zinc Sheath.
What does E mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? E means Polyethylene (PE).
What does R mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? R means Natural Or Synthetic Rubber (Today: Ethylene-Propylene Rubber Or Equivalent Elastomer, 60 °C).
Work with 1-CXKE-R
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.
Related cables
More HAR: HD 361 harmonised designation (CENELEC) designations