(N)A2XY 1X240 RM 1.5/1.5 DC kV

(N)A2XY 1X240 RM 1.5/1.5 DC kV is a BIS type names (India) cable designation: A = Aluminium conductor; 2X = Cross-linked polyethylene (XLPE) insulation; Y = PVC outer sheath; 1X240 = 240 mm², 1 conductor; (N) = Has a neutral core (blue insulation); A2XY = A2XY: aluminium conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V). Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit. IS 7098 (Part 1):2025, cable code cl. 18.3.

2 coding systems recognise this code

BIS type names (India)

SymbolMeaning
AAluminium conductor
2XCross-linked polyethylene (XLPE) insulation
YPVC outer sheath
1X240240 mm², 1 conductor
(N)Has a neutral core (blue insulation)
A2XYA2XY: aluminium conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V). Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit. IS 7098 (Part 1):2025, cable code cl. 18.3

DIN VDE 0271/0276 power cables (Germany)

SymbolMeaning
(N)Similar To VDE Standard
AAluminium Conductor
2XCross-Linked Polyethylene (XLPE)
YPolyvinyl Chloride (PVC)
RMRound Stranded Conductor, IEC 60228 Class 2

How to read a DIN VDE 0271/0276 power cables (Germany) cable code

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

(N)A2XY 1X240 RM 1.5/1.5 DC kV as the cable designer builds it, 1x240 1100 V

Overall diameter 25.8 mm, about 980 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationXLPE1.721.8
SheathPVC2.025.8

(N)A2XY 1X240 RM 1.5/1.5 DC kV on a drum

The smallest drum that passes every check, for 25.8 mm and about 980 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates within a few per cent of the cable makers' own tables: whole layers, wound diameter 1.05 × OD, 50 mm freeboard under the flange rim.

LengthDrum size (its makers)LayersGross weight
500 mKTG 12 (1250 mm flange), wood KTG drums (Europe), Bayka, KTG8 of 9634–655 kg
1,000 mKTG 16 (1600 mm flange), wood KTG drums (Europe), Bayka, KTG10 of 121,256–1,289 kg

Barrel at least 20 × OD = 516 mm for a cable of this kind (Low voltage, single core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: (N)A2XY 1X240 RM 1.5/1.5 DC kV