Kablo kodu nasıl okunur: kodlama sistemine göre rehberler · BIS type names (India) · Hindistan

BIS type names (India): kablo tipi adları nasıl okunur

BIS type names (India) içindeki her ad bütün bir kablo tipini anlatır: örneğin A2XY kendi yapısı, standardı ve anma değerleriyle gelir. Çözümleyici bu sistemin 18 tipini biliyor. Aşağıda adların nasıl kurulduğu, anma değerleriyle tüm tipler ve tablonun dayandığı kaynaklar var.

Ad nasıl kurulur

Tip tablosu her adı parçalarına ayırır ve her parçanın anlamını kaydeder. Parçalarına ayrılmış birkaç ad:

A2XY

AAluminium conductor
2XCross-linked polyethylene (XLPE) insulation
YPVC outer sheath

A2XY: aluminium conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V)

2XY

2XCross-linked polyethylene (XLPE) insulation
YPVC outer sheath

2XY: copper conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V)

A2XFY

AAluminium conductor
2XCross-linked polyethylene (XLPE) insulation
FFlat Galvanized Steel Wire (Strip) Armour
YPVC outer sheath

A2XFY: aluminium conductors, XLPE insulation, inner sheath, galvanised steel strip (formed wire) armour, PVC outer sheath (IS 7098-1, up to 1100 V)

2XWY

2XCross-linked polyethylene (XLPE) insulation
WRound steel wire armour
YPVC outer sheath

2XWY: copper conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V)

Adlarda kullanılan tüm parçalar

ParçaAnlamıKullanıldığı tipler
YPVC outer sheathAYFY AYWY YFY YWY A2XFY A2XWY 2XFY 2XWY A2XY 2XY
2XCross-linked polyethylene (XLPE) insulationA2XFY A2XWY 2XFY 2XWY A2XY 2XY
AAluminium conductorAYFY AYWY A2XFY A2XWY A2XY
YPVC insulationAYFY AYWY YFY YWY
FFlat Galvanized Steel Wire (Strip) ArmourAYFY YFY A2XFY 2XFY
WRound steel wire armourAYWY YWY A2XWY 2XWY
FRFlame RetardantFRLS FR WIRE
PVCPVC insulationFR WIRE IS 1554-2
SCSemiconducting Layer And Screen Over Each CoreHT XLPE IS 1554-2
CUCopper Tape ScreenHT XLPE IS 1554-2
ARMArmourHT XLPE IS 1554-2
PVCPVC outer sheathHT XLPE IS 1554-2
LSLow Smoke Low Halogen PvcFRLS
HFFRHalogen-Free Flame-Retardant CompoundHFFR WIRE
FLEXIBLEFlexible conductor (class 5)MULTICORE FLEXIBLE
HTHigh tension (HT) XLPE cable of IS 7098-2, for 3.3 kV up to 33 kV, each core screenedHT XLPE
XLPECross-linked polyethylene (XLPE) insulationHT XLPE

BIS type names (India) içindeki tüm tipler

TipAçıklamaAnma değerleri
FRLSFRLS / FR-LSH house wire: one copper conductor, flame-retardant PVC insulation with reduced smoke and acid gas emissionUp to and including 1100 V; -15 to +70 C (RR Kabel, Polycab)
FR WIREFR house wire: one copper conductor, flame-retardant PVC insulation1100 V AC (Polycab ETIRA FR)
HFFR WIREHFFR house wire: one flexible copper conductor, halogen-free flame-retardant insulationUp to and including 1100 V; -15 to +70 C, 160 C short circuit (RR Kabel LS0H-FR)
MULTICORE FLEXIBLEMulticore flexible cable: class 5 copper cores in PVC under a PVC sheath, in the general purpose, FR or FR-LSH grade (IS 694 Tables 6, 7 and 9)1100 V (IS 694 Amendment No. 3, 2015)
AYFYAYFY: aluminium conductors, PVC insulation, inner sheath, galvanised steel strip (formed wire) armour, PVC outer sheath (IS 1554-1, up to 1100 V)Up to and including 1100 V a.c.; d.c. up to and including 1500 V to earth; 70 C (Type A PVC) or 85 C (Type C, marked HR 85), 160 C short circuit
AYWYAYWY: aluminium conductors, PVC insulation, inner sheath, galvanised round steel wire armour, PVC outer sheath (IS 1554-1, up to 1100 V)Up to and including 1100 V a.c.; d.c. up to and including 1500 V to earth; 70 C (Type A PVC) or 85 C (Type C, marked HR 85), 160 C short circuit
YFYYFY: copper conductors, PVC insulation, inner sheath, galvanised steel strip (formed wire) armour, PVC outer sheath (IS 1554-1, up to 1100 V)Up to and including 1100 V a.c.; d.c. up to and including 1500 V to earth; 70 C (Type A PVC) or 85 C (Type C, marked HR 85), 160 C short circuit
YWYYWY: copper conductors, PVC insulation, inner sheath, galvanised round steel wire armour, PVC outer sheath (IS 1554-1, up to 1100 V)Up to and including 1100 V a.c.; d.c. up to and including 1500 V to earth; 70 C (Type A PVC) or 85 C (Type C, marked HR 85), 160 C short circuit
A2XFYA2XFY: aluminium conductors, XLPE insulation, inner sheath, galvanised steel strip (formed wire) armour, PVC outer sheath (IS 7098-1, up to 1100 V)Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit
A2XWYA2XWY: aluminium conductors, XLPE insulation, inner sheath, galvanised round steel wire armour, PVC outer sheath (IS 7098-1, up to 1100 V)Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit
2XFY2XFY: copper conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V)Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit
2XWY2XWY: copper conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V)Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit
A2XYA2XY: aluminium conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V)Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit
2XY2XY: copper conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V)Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit
IS 1554-1IS 1554-1: PVC-insulated, PVC-sheathed power cable up to and including 1.1 kV (the letter name, AYFY or AYWY, says the metal and the armour)Up to and including 1100 V a.c.; d.c. up to and including 1500 V to earth; 70 C (Type A PVC) or 85 C (Type C, marked HR 85), 160 C short circuit
IS 7098-1IS 7098-1: XLPE-insulated, PVC-sheathed power cable up to and including 1.1 kV (the letter name, A2XFY or A2XWY, says the metal and the armour)Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit
HT XLPEHT XLPE: XLPE-insulated cable for 3.3 kV up to 33 kV, each core with a conductor screen, XLPE insulation, an insulation screen and copper tape; PVC fillers and inner sheath, steel round wire or flat strip armour, PVC outer sheathEarthed 1.9/3.3, 3.8/6.6, 6.35/11, 12.7/22, 19/33 kV, unearthed 3.3/3.3 and 11/11 kV; 90 C normal, 250 C short circuit (BIS catalogue); RR Kabel sells 6.35/11 kV (E)
IS 1554-2HT PVC: PVC-insulated heavy duty cable for 3.3 kV up to 11 kV; at 6.35/11 kV each core with a conductor screen, PVC insulation, an insulation screen and a metallic screen; PVC fillers and inner sheath, steel round wire or formed wire (strip) armour, PVC outer sheath1.9/3.3, 3.3/3.3, 3.8/6.6 and 6.35/11 kV; 70 C normal, 160 C short circuit

Sık sorulanlar

A2XY kablosu nedir?

A2XY: aluminium conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V). Anma değerleri: Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit. Standart: IS 7098 (Part 1):2025, cable code cl. 18.3. Adın okunuşu: A (Aluminium conductor) + 2X (Cross-linked polyethylene (XLPE) insulation) + Y (PVC outer sheath).

2XY kablosu nedir?

2XY: copper conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V). Anma değerleri: Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit. Standart: IS 7098 (Part 1):2025, cable code cl. 18.3. Adın okunuşu: 2X (Cross-linked polyethylene (XLPE) insulation) + Y (PVC outer sheath).

A2XY ile 2XY arasındaki fark nedir?

A2XY: aluminium conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V), Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit. 2XY: copper conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V), Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit. Adlar şu parçalarda ayrılır: A2XY: A (Aluminium conductor).

BIS type names (India): kablo adındaki Y ne demek?

Y tipe göre birden fazla anlama gelir: PVC outer sheath (AYFY, AYWY, YFY, YWY +6); PVC insulation (AYFY, AYWY, YFY, YWY).

A2XFY kablosu nedir?

A2XFY: aluminium conductors, XLPE insulation, inner sheath, galvanised steel strip (formed wire) armour, PVC outer sheath (IS 7098-1, up to 1100 V). Anma değerleri: Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit. Standart: IS 7098 (Part 1):2025, cable code cl. 18.3. Adın okunuşu: A (Aluminium conductor) + 2X (Cross-linked polyethylene (XLPE) insulation) + F (Flat Galvanized Steel Wire (Strip) Armour) + Y (PVC outer sheath).

2XWY kablosu nedir?

2XWY: copper conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V). Anma değerleri: Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit. Standart: IS 7098 (Part 1):2025, cable code cl. 18.3. Adın okunuşu: 2X (Cross-linked polyethylene (XLPE) insulation) + W (Round steel wire armour) + Y (PVC outer sheath).

Tip tablosunun dayandığı kaynaklar

Tabloda adı geçen standartlar

  • IS 694:2010 (cable code cl. 13)
  • insulation IS 5831
  • conductor IS 8130
  • flammability IEC 60332-1 (Polycab)
  • IS 17048:2018 (cable code cl. 7)
  • IS 694:2010 + Amd 3:2015, Tables 6, 7 and 9
  • insulation and sheath IS 5831
  • IS 1554 (Part 1):1988 (reaffirmed 2020), cable code cl. 17.3
  • IS 7098 (Part 1):2025, cable code cl. 18.3
  • IS 1554 (Part 1):1988 (reaffirmed 2020)
  • IS 7098 (Part 1):2025
  • IS 7098-2:2011
  • IS 1554 (Part 2):1988 (reaffirmed 2020)

Okumaların alındığı belgeler ve sayfalar

Bu sitenin tip tablosundan, yukarıda adı geçen kaynaklarla alınmıştır. Bir kabloyu şartnameye yazmadan önce üreticinin veri sayfasına bakın.

BIS type names (India) içindeki tüm tipler · Kendi kodunuzu çözümleyin