TW75

TW75, CSA (Kanada) kodlama sistemine göre okunan bir kablo kodudur: T = Thermoplastic (PVC) insulation: CSA C22.1:24 Table 19 (p. 469) groups T90 Nylon, TW, TW75 and TWN75 as thermoplastic insulated conductors and TWU, TWU75 as thermoplastic cable; UL 83 / CSA C22.2 No. 75-17 Table C1: PVC; W = Suitable for wet locations: CSA C22.1:24 Table 19 (p. 469) allows TW, TW75, TWN75, TWU and TWU75 in wet locations and T90 Nylon (no W) not; UL 83 / CSA C22.2 No. 75-17 Table C1: TW75 75 C dry or wet, T90 Nylon 90 C dry; 75 = Maximum conductor temperature 75 C; TW75 = PVC building wire, 75 C, older construction replaced by T90. 600 V, 75 C. CSA C22.2 No. 75.

1 kodlama sistemi bu kodu tanıyor

Standart, örnek okuma ve ilgili tipler

TW75 örnek okuma:

  • TW75: T = Thermoplastic (PVC) insulation: CSA C22.1:24 Table 19 (p. 469) groups T90 Nylon, TW, TW75 and TWN75 as thermoplastic insulated conductors and TWU, TWU75 as thermoplastic cable; UL 83 / CSA C22.2 No. 75-17 Table C1: PVC; W = Suitable for wet locations: CSA C22.1:24 Table 19 (p. 469) allows TW, TW75, TWN75, TWU and TWU75 in wet locations and T90 Nylon (no W) not; UL 83 / CSA C22.2 No. 75-17 Table C1: TW75 75 C dry or wet, T90 Nylon 90 C dry; 75 = Maximum conductor temperature 75 C; TW75 = PVC building wire, 75 C, older construction replaced by T90. 600 V, 75 C. CSA C22.2 No. 75

İlgili kablo tipleri: RW75

CSA (Kanada)

SembolAnlamı
TThermoplastic (PVC) insulation: CSA C22.1:24 Table 19 (p. 469) groups T90 Nylon, TW, TW75 and TWN75 as thermoplastic insulated conductors and TWU, TWU75 as thermoplastic cable; UL 83 / CSA C22.2 No. 75-17 Table C1: PVC
WSuitable for wet locations: CSA C22.1:24 Table 19 (p. 469) allows TW, TW75, TWN75, TWU and TWU75 in wet locations and T90 Nylon (no W) not; UL 83 / CSA C22.2 No. 75-17 Table C1: TW75 75 C dry or wet, T90 Nylon 90 C dry
75Maximum conductor temperature 75 C
TW75PVC building wire, 75 C, older construction replaced by T90. 600 V, 75 C. CSA C22.2 No. 75

TW75 kablosu nedir?

TW75: PVC building wire, 75 C, older construction replaced by T90. Anma değerleri: 600 V, 75 C. Standart: CSA C22.2 No. 75.

Okumaların alındığı belgeler ve sayfalar

  • sycor.com
  • sycor.com
  • CSA C22.1:24: Canadian Electrical Code, Part I (March 2024), Table 19 (pp. 469-474) and Appendix D Table D1 (pp. 766-773), read 2026-11-11 (the Rules, Sections 0 to 86, not held)
  • UL 83 ed. 16 / CSA C22.2 No. 75-17 / NMX-J-010-ANCE-2017: Thermoplastic-Insulated Wires and Cables, Tables C1 and A1, read 2026-11-08

CSA (Kanada): kablo tipi adları nasıl okunur

Yangın davranışı (AB CPR)

CPR sınıfını üretici Performans Beyanında beyan eder ve kılıfa basar (EN 50575 md. 7). Bu çözümleyici sınıf atamaz. CPR sınıfları ne anlama gelir →

Kaynaklar: EN 13501-6 taslağı ve FprEN 50575:2014 son taslağı (taslaklar, yayımlanmış metin değil); IEC 60332-3-24:2000+A1:2008; EN 13501-3 A2 taslağı.

Döşeme, kesitler ve veri sayfası: TW75

Kesitleri AWG ve kcmil cinsindendir; bunlar en yakın mm² ile aynı değildir: alana ve dirence göre karşılaştırın. AWG'den mm²'ye

TW75 ile çalışın

Bu kabloyu kim üretiyor veya stokluyor?

Bu kablo ailesinin üreticileri ve stokçuları burada bölgeniz için sponsor olarak yer alır, her biri "Sponsorlu" diye işaretlenir; bir listeleme bu sayfanın kablo hakkında söylediklerini asla değiştirmez.

İlgili kablolar

Diğer CSA (Kanada) kodları

TW75