NYRUZY

NYRUZY, DIN VDE tip adları (Almanya) kodlama sistemine göre okunan bir kablo kodudur: N = German national (VDE) type; Y = Thermoplastic (PVC) core insulation; RUZ = Umhüllter Rohrdraht: a folded zinc tape sheath (grooved allowed) over the common covering of the cores; Y = Thermoplastic (PVC) outer covering; NYRUZY = NYRUZY: covered tube wire (umhüllter Rohrdraht), PVC insulated copper cores under a common covering, a folded zinc tape sheath and a thermoplastic outer covering, 500 V. 500 V; fixed laying in dry and damp rooms, on and under plaster and outdoors; conductor at most 70 °C. DIN 47707:1970-11 (Umhüllte Rohrdrähte NYRUZY: use, dimensions, weights; withdrawn, a decoder reading only, not a current standard).

1 kodlama sistemi bu kodu tanıyor

DIN VDE tip adları (Almanya)

SembolAnlamı
NGerman national (VDE) type
YThermoplastic (PVC) core insulation
RUZUmhüllter Rohrdraht: a folded zinc tape sheath (grooved allowed) over the common covering of the cores
YThermoplastic (PVC) outer covering
NYRUZYNYRUZY: covered tube wire (umhüllter Rohrdraht), PVC insulated copper cores under a common covering, a folded zinc tape sheath and a thermoplastic outer covering, 500 V. 500 V; fixed laying in dry and damp rooms, on and under plaster and outdoors; conductor at most 70 °C. DIN 47707:1970-11 (Umhüllte Rohrdrähte NYRUZY: use, dimensions, weights; withdrawn, a decoder reading only, not a current standard)

NYRUZY kablosu nedir?

NYRUZY: covered tube wire (umhüllter Rohrdraht), PVC insulated copper cores under a common covering, a folded zinc tape sheath and a thermoplastic outer covering, 500 V. Anma değerleri: 500 V; fixed laying in dry and damp rooms, on and under plaster and outdoors; conductor at most 70 °C. Standart: DIN 47707:1970-11 (Umhüllte Rohrdrähte NYRUZY: use, dimensions, weights; withdrawn, a decoder reading only, not a current standard).

Okumaların alındığı belgeler ve sayfalar

  • DIN 47707:1970-11 (p. 1, the construction drawing and the dimension table)

DIN VDE tip adları (Almanya): kablo tipi adları nasıl okunur

Yangın davranışı (AB CPR)

CPR sınıfını üretici Performans Beyanında beyan eder ve kılıfa basar (EN 50575 md. 7). Bu çözümleyici sınıf atamaz. CPR sınıfları ne anlama gelir →

Kaynaklar: EN 13501-6 taslağı ve FprEN 50575:2014 son taslağı (taslaklar, yayımlanmış metin değil); IEC 60332-3-24:2000+A1:2008; EN 13501-3 A2 taslağı.