CMP-LP er en kabelbetegnelse efter NEC / UL (USA): C = Communications cable; M = Multipurpose rating (reading by usage, UNVERIFIED); P = Plenum; LP = Limited power: rated current per conductor printed, for power over Ethernet (NEC 2023); CMP-LP = Communications cable, plenum rated (low smoke, FEP insulation), limited power (LP): marked with the current per conductor for PoE. 300 V, 75 C. UL 444; NEC 800.179(A).
2 kodesystemer genkender denne betegnelse
NEC / UL (USA)
| Symbol | Betydning |
|---|---|
C | Communications cable |
M | Multipurpose rating (reading by usage, UNVERIFIED) |
P | Plenum |
LP | Limited power: rated current per conductor printed, for power over Ethernet (NEC 2023) |
CMP-LP | Communications cable, plenum rated (low smoke, FEP insulation), limited power (LP): marked with the current per conductor for PoE. 300 V, 75 C. UL 444; NEC 800.179(A) |
NBN
| Symbol | Betydning |
|---|---|
C | Gummi (kautsjuk), natur eller syntetisk, isolering eller kappe |
M | Middel belastning / isolering (500 V; 450/750 V i 2011-kataloget) |
P | Papirisolering og blykappe |
L | Let belastning / isolering (300 V; 300/500 V i 2011-kataloget) |
P | Papirisolering og blykappe |
Brandegenskaber (EU-byggevareforordningen, CPR)
Blanding med lav røgudvikling (CMP-LP). Røg inddeles i s1 til s3 på EN 50399-skalaen; ved s1a og s1b kommer 3 m-kubeprøvningen EN 61034-2 til.
En CPR-klasse deklareres af producenten i ydeevnedeklarationen og trykkes på kappen (EN 50575 pkt. 7). Denne afkoder tildeler ingen klasse. Hvad CPR-klasserne betyder →
Kilder: udkast til EN 13501-6 og slutudkast FprEN 50575:2014 (udkast, ikke de offentliggjorte tekster); IEC 60332-3-24:2000+A1:2008; udkast til EN 13501-3 A2.