THW IEC01
THW IEC01 is a TIS 11 type names (Thailand) cable designation: THW = THW: Thai name of the single-core PVC-insulated building wire 60227 IEC 01 (TIS 11 Part 3), printed "THW IEC01"; not the US THW; THW = THW (Thailand): single-core PVC-insulated copper building wire, 60227 IEC 01. 450/750 V, 70 C (Thai Cable Wires; Yazaki listing). TIS 11 Part 3-2553 (60227 IEC 01).
1 coding system recognises this code
TIS 11 type names (Thailand)
| Symbol | Meaning |
|---|---|
THW | THW: Thai name of the single-core PVC-insulated building wire 60227 IEC 01 (TIS 11 Part 3), printed "THW IEC01"; not the US THW |
THW | THW (Thailand): single-core PVC-insulated copper building wire, 60227 IEC 01. 450/750 V, 70 C (Thai Cable Wires; Yazaki listing). TIS 11 Part 3-2553 (60227 IEC 01) |
Fire behaviour (EU CPR)
PVC sheath (THW).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
THW IEC01 as the cable designer builds it, 1x1.5 450/750 V
Overall diameter 2.8 mm, about 20 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.
| Layer | Material | Thickness, mm | Over the layer, mm |
|---|---|---|---|
| Insulation | PVC | 0.70 | 2.8 |
THW IEC01 on a drum
The smallest drum that passes every check, for 2.8 mm and about 20 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates within a few per cent of the cable makers' own tables: whole layers, wound diameter 1.05 × OD, 50 mm freeboard under the flange rim.
| Length | Drum size (its makers) | Layers | Gross weight |
|---|---|---|---|
| 500 m | KTG 3 (390 mm flange), plastic KTG drums (Europe), KTG | 8 of 28 | 12 kg |
| 1,000 m | KTG 3 (390 mm flange), plastic KTG drums (Europe), KTG | 14 of 28 | 22 kg |
Barrel at least 20 × OD = 56 mm for a cable of this kind (Low voltage, single core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own.
Other lengths, drums and weights: the cable drum calculator
Load it on a truck: 1000 m on its drum in the loading planner
Laying, sizes and datasheet: THW IEC01
Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro