JE-LiYCY-BD
JE-LiYCY-BD is a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable designation: J = Installation Cable; E = For Industrial Electronics; Li = Stranded Conductor, Flexible (Litzenleiter To VDE 0812); Y = Polyvinyl Chloride (PVC); C = Copper Screen As Braid; Y = Polyvinyl Chloride (PVC); B = Helical Galvanized Steel Tape; D = Copper Wire Screen, Helically Applied (Copper Serving).
1 coding system recognises this code
VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888)
| Symbol | Meaning |
|---|---|
J | Installation Cable |
E | For Industrial Electronics |
Li | Stranded Conductor, Flexible (Litzenleiter To VDE 0812) |
Y | Polyvinyl Chloride (PVC) |
C | Copper Screen As Braid |
Y | Polyvinyl Chloride (PVC) |
B | Helical Galvanized Steel Tape |
D | Copper Wire Screen, Helically Applied (Copper Serving) |
How to read a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code
Fire behaviour (EU CPR)
PVC sheath (Y).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with JE-LiYCY-BD
Related cables
More VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) designations