2XY 0,6 (3G120

2XY 0,6 (3G120 is a BIS type names (India) cable designation: 2X = Cross-linked polyethylene (XLPE) insulation; Y = PVC outer sheath; 3G120 = 120 mm², 3 conductors; 2XY = 2XY: copper conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V). Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit. IS 7098 (Part 1):2025, cable code cl. 18.3.

1 coding system recognises this code

BIS type names (India)

SymbolMeaning
2XCross-linked polyethylene (XLPE) insulation
YPVC outer sheath
3G120120 mm², 3 conductors
2XY2XY: copper conductors, XLPE insulation, inner sheath, unarmoured, PVC outer sheath (IS 7098-1, up to 1100 V). Up to and including 1100 V a.c.; d.c. up to and including 1500 V; 90 C normal, 250 C short circuit. IS 7098 (Part 1):2025, cable code cl. 18.3

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

2XY 0,6 (3G120 as the cable designer builds it, 3x120 1100 V

Overall diameter 38.2 mm, about 4,040 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationXLPE1.215.3
FillerPP33.0
Inner covering / beddingPVC0.4033.8
SheathPVC2.238.2

2XY 0,6 (3G120 on a drum

The smallest drum that passes every check, for 38.2 mm and about 4,040 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates within a few per cent of the cable makers' own tables: whole layers, wound diameter 1.05 × OD, 50 mm freeboard under the flange rim.

LengthDrum size (its makers)LayersGross weight
500 mKTG 16 (1600 mm flange), wood KTG drums (Europe), Bayka, KTG8 of 82,296–2,329 kg
1,000 mKTG 20 (2000 mm flange), wood KTG drums (Europe), Bayka, KTG8 of 84,519–4,640 kg

Barrel at least 15 × OD = 573 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: 2XY 0,6 (3G120