Slik leser du en typebetegnelse: guider per betegnelsessystem · NEC / UL (USA) · USA

NEC / UL (USA): slik leser du kabeltypenavnene

Hvert navn i NEC / UL (USA) står for en hel kabeltype: THW har for eksempel sin egen konstruksjon, standard og egne merkedata. Dekoderen kjenner 133 typer i dette systemet. Nedenfor: hvordan navnene er bygd opp, hver type med sine merkedata og kildene tabellen nevner.

Slik er et navn bygd opp

Typetabellen deler hvert navn opp i deler og angir hva hver del betyr. Noen navn tatt fra hverandre:

THW

TThermoplastic (PVC) insulation
HHeat resistant, 75 C (one H)
WApproved for wet locations

Thermoplastic heat- and moisture-resistant building wire, 75 C

THHN

TThermoplastic (PVC) insulation
HHHigh heat resistant, 90 C (one H means 75 C)
NNylon outer covering

Thermoplastic high heat-resistant nylon-coated building wire

SOOW

SService cord, 600 V, extra-hard usage
OOOil-resistant insulation (inner) and jacket (outer)
WWeather- and water-resistant

Standard thermoset flexible cord, oil-resistant, weather-resistant

CMP

CCommunications cable
MMultipurpose rating (reading by usage, UNVERIFIED)
PPlenum

Communications cable, plenum rated (low smoke; FEP insulation on 4-pair data cable, low-smoke PVC on 2-conductor cable)

Alle deler som brukes i navnene

DelBetydningBrukes i
WWeather- and water-resistantSOW SOOW SJOW SJOOW SJTW SJTOW SJTOOW STW STOW STOOW SEOW SEOOW SJEOOW
SService cord, 600 V, extra-hard usageSO SOO SOW SOOW ST STW STO STOW STOOW SEOW SEOOW
TThermoplastic (PVC) insulationTW THW THHW THWN THHN THWN-2 TFFN TFN TFF TF
TThermoplastic (PVC) insulation and jacketSJT SJTW SJTO SJTOW SJTOOW ST STW STO STOW STOOW
OOil-resistant outer jacketSO SOW SJO SJOW SJTO SJTOW STO STOW SEOW
SJJunior service cord, 300 V, lighter dutySJO SJOW SJOOW SJT SJTW SJTO SJTOW SJTOOW SJEOOW
CCommunications cableCM CMP CMR CMG CMX CMP-LP CMR-LP CMG-LP CM-LP
MMultipurpose rating (reading by usage, UNVERIFIED)CM CMP CMR CMG CMX CMP-LP CMR-LP CMG-LP CM-LP
WApproved for wet locationsTHW THHW THWN THWN-2 XHHW XHHW-2 RHW RHW-2
RRiserCMR CL2R CL3R OFNR OFCR CATVR CMR-LP NPLFR
CLClass 2 or 3 power-limited circuit cableCL2 CL2R CL2P CL2X CL3 CL3R CL3P CL3X
OFOptical fibreOFN OFNG OFNR OFNP OFC OFCR OFCP OFCG
OOOil-resistant insulation (inner) and jacket (outer)SOO SOOW SJOOW SJTOOW STOOW SEOOW SJEOOW
PPlenumCMP OFNP OFCP CATVP CMP-LP NPLFP
AWMAppliance wiring material, UL 758: a style number, not an NEC wiring typeAWM 1007 AWM 1015 AWM 2464 AWM 2517 AWM 2919 AWM 20276
NNylon outer coveringTHWN THHN THWN-2 TFFN TFN
SService cordSPT-1 SPT-2 SPT-3 SPT SVT
TThermoplastic (PVC)SPT-1 SPT-2 SPT-3 SPT SVT
-290 C in both wet and dry locationsTHWN-2 XHHW-2 RHW-2 USE-2
HHHigh heat resistant, 90 CXHH XHHW XHHW-2 RHH
PParallel (zip) constructionSPT-1 SPT-2 SPT-3 SPT
2Class 2 circuitCL2 CL2R CL2P CL2X
3Class 3 circuitCL3 CL3R CL3P CL3X
NNonconductive (dielectric)OFN OFNG OFNR OFNP
CConductive (metallic member, UNVERIFIED)OFC OFCR OFCP OFCG
LPLimited power: rated current per conductor printed, for power over Ethernet (NEC 2023)CMP-LP CMR-LP CMG-LP CM-LP
XThermoset (cross-linked polyethylene) insulationXHH XHHW XHHW-2
RThermoset (originally rubber) insulationRHH RHW RHW-2
TCTray cableTC-ER TC-ER-HL TC-ER-JP
ERExposed run (NEC 336.10(7)): passes the UL 1277 impact and crush tests; a grounding conductor unless three or more circuit conductors none over 6 AWG (UL 1277 ed. 6, 8.7, 30.1(p))TC-ER TC-ER-HL TC-ER-JP
EThermoplastic elastomer (TPE) insulation and jacket (reading from Seoprene pages; E alone UNVERIFIED)SEOW SEOOW SJEOOW
XLimited use (VW-1 vertical flame test)CMX CL2X CL3X
CATVCommunity antenna television (coaxial) cable, NEC 820CATVR CATVP CATVX
HHeat resistant, 75 C (one H)THW THWN
HHeat resistantTHWN-2 RHW-2
UUnderground, direct burialUSE USE-2
SEService entranceUSE USE-2
FFFlexible fixture (stranded) wireTFFN TFF
FFixture wireTFN TF
-BConductors rated 90 CNM-B UF-B
SEService-entrance cableSER SEU
ITCInstrumentation tray cableITC-ER ITC-HL
ERExposed runITC-ER PLTC-ER
PLTCPower-limited tray cablePLTC-ER PLTC-HL
MVMedium voltageMV-90 MV-105
GGrounded portable power cable (UNVERIFIED)TYPE G G-GC
PPlenum (NFPA 262 tunnel test)CL2P CL3P
FPLFire alarm, power limitedFPLR FPLP
GGeneral purposeOFNG CMG-LP
NPLFNon-power-limited fire alarm cable (NEC 760 Part II)NPLFR NPLFP
HLHazardous location: welded corrugated aluminium sheath under the jacketITC-HL PLTC-HL
SHDShielded, heavy duty: each phase core under a flexible copper braid shield (Prysmian: Shielded Round)SHD-GC SHD-CGC
GCGround-check conductor, yellow polypropylene insulated, for fail-safe ground monitoringSHD-GC MP-GC
WMoisture resistant, wet locationsTW
HHHigh heat resistant, 90 C range (two H)THHW
HHHigh heat resistant, 90 C (one H means 75 C)THHN
HHeat resistant, 75 CRHW
NMNon-metallic sheathed cableNM-B
UFUnderground feeder, direct burialUF-B
RRound cable with separate neutral and ground (reading by usage, UNVERIFIED)SER
UFlat (oval) cable with a concentric bare neutral (reading by usage, UNVERIFIED)SEU
ACArmored cable, interlocked armourAC
90Conductors rated 90 C (AC-90 / ACHH)AC
MCMetal-clad cableMC-HL
-HLHazardous locations, Class I, II, III Div 1 and 2 and Class I Zones 1 and 2MC-HL
HLHazardous locations: a TC-ER cable that also meets UL 2225 (UL 1277 ed. 6, 30.1(t))TC-ER-HL
-90Conductor temperature rating 90 C (emergency 130 C, short circuit 250 C)MV-90
-105Conductor temperature rating 105 C (emergency 140 C, short circuit 250 C)MV-105
XLPECross-linked polyethylene insulation; the number before it is the wall in mils (AEIC CS9-06 Appendix E Table E-1, by voltage class)AEIC-CS9
-1Insulation thickness class 1 (UNVERIFIED)SPT-1
-2Insulation thickness class 2 (0.045 in on the AWC page)SPT-2
-3Insulation thickness class 3 (UNVERIFIED)SPT-3
VVacuum cleaner / appliance (UNVERIFIED)SVT
SVTService vacuum thermoplastic cordSVTO
OOil-resistant jacketSVTO
HHeater cord (UNVERIFIED)HPN
PParallel construction (UNVERIFIED)HPN
NNeoprene insulation (UNVERIFIED)HPN
WPortable power cable type W (weather and water resistant)TYPE W
GCGround-check conductor (UNVERIFIED)G-GC
PVPhotovoltaic wirePV WIRE
GGeneral purpose (FT4 vertical flame test)CMG
RRiser (UL 1666)FPLR
PPlenum (UL 910, low smoke)FPLP
1007Style 1007: 300 V a.c., 80 C, 32 to 16 AWG, PVC insulationAWM 1007
1015Style 1015: 600 V a.c. or 750 V d.c., 80 / 90 / 105 C, 30 AWG to 2000 kcmil, PVC insulationAWM 1015
2464Style 2464: 300 V a.c., 80 C, multi-conductor with a jacketAWM 2464
2517Style 2517: 300 V a.c., 105 C, multi-conductor with a jacketAWM 2517
2919Style 2919: 30 V a.c., 80 C, multi-conductor with a jacketAWM 2919
20276Style 20276: 30 V a.c., 60 or 80 C, multi-conductor with a jacketAWM 20276
JPJoist pull: passed the UL 1277 joist-pull test (NEC 336.10)TC-ER-JP
XLimited useCATVX
GGeneral purpose (UL 1685 vertical tray), not for risers or plenumsOFCG
CMCommunications cable (NEC 800)CMUC
UCUnder carpetCMUC
CGCExtensible centre ground-check conductor, stranded to stretch without carrying tensile loadSHD-CGC
MPMine power feeder cable for permanent installation (Prysmian: Mine Power Feeder)MP-GC

Hva typetabellen sier om navnene

Sitert fra typetabellens merknader, med typene de hører til.

  • Usually dual-marked THHN/THWN-2 (and MTW when stranded): the reader treats each name as one listing of the same wire. (THHN)
  • Romex is Southwire's brand, used as the type name. (NM-B)
  • BX is the trade name for AC. (AC)
  • C-L-X is Southwire/Okonite's trade name for this build. (MC-HL)
  • Written "12/3": 12 AWG, 3 conductors counting the green ground. (S, SO, SOO, SOW, SOOW, SJ +14)

Alle typer i NEC / UL (USA)

TypeBeskrivelseMerkedata
TWThermoplastic moisture-resistant building wire, 60 C600 V, 60 C dry and wet
THWThermoplastic heat- and moisture-resistant building wire, 75 C600 V, 75 C dry and wet
THHWThermoplastic high heat-resistant, moisture-resistant building wire600 V, 90 C dry, 75 C wet
THWNThermoplastic heat- and water-resistant nylon-coated building wire, 75 C600 V, 75 C wet and dry
THHNThermoplastic high heat-resistant nylon-coated building wire600 V, 90 C dry and damp locations
THWN-2Thermoplastic heat- and water-resistant nylon-coated building wire, 90 C wet or dry600 V, 90 C wet and dry locations
MTWMachine tool wire, oil-resistant PVC, 90 C600 V, 90 C dry, 60 C wet or oil
XHHThermoset (XLPE) high heat-resistant building wire, dry and damp locations600 V, 90 C dry and damp
XHHWThermoset (XLPE) high heat-resistant building wire, wet locations at 75 C600 V, 90 C dry, 75 C wet
XHHW-2Thermoset (XLPE) high heat-resistant building wire, 90 C wet or dry600 V, 90 C wet and dry
RHHThermoset (rubber-type) high heat-resistant building wire, dry and damp600 V, 90 C dry and damp
RHWThermoset (rubber-type) heat- and moisture-resistant building wire, 75 C600 V, 75 C dry and wet
RHW-2Thermoset (rubber-type) heat- and moisture-resistant building wire, 90 C wet or dry600 V (2 kV on some listings), 90 C wet and dry
USEUnderground service-entrance conductor (single wire), 75 C600 V, 75 C
USE-2Underground service-entrance conductor, 90 C wet or dry600 V, 90 C wet and dry
TBSThermoplastic-insulated, braid-covered switchboard wire600 V, 90 C
SISSwitchboard and control wire, cross-linked polyethylene, 90 C600 V, 90 C
TFFNThermoplastic flexible fixture wire, nylon-coated600 V, 90 C
TFNThermoplastic fixture wire, nylon-coated (solid conductor)600 V, 90 C
TFFThermoplastic flexible fixture wire, no nylon600 V, 60 C (UNVERIFIED)
TFThermoplastic fixture wire, no nylon600 V, 60 C
NM-BNon-metallic sheathed cable, type B (90 C conductors), for dry indoor wiring600 V, 90 C conductors (ampacity at the 60 C column)
UF-BUnderground feeder cable, type B, sunlight-resistant gray jacket, direct burial600 V, 90 C conductors (ampacity at the 60 C column)
SEService-entrance cable (general term, SER round or SEU flat)600 V, 75 or 90 C
SERService-entrance cable, style R (round), with a bare ground, gray jacket600 V, 90 C (XLPE) or 75 C (PVC)
SEUService-entrance cable, style U (flat), with a concentric bare neutral, gray jacket600 V, 90 C (XLPE) or 75 C (PVC)
URDUnderground residential distribution cable, twisted aluminium conductors, direct burial600 V, 90 C XLPE
MOBILE HOME FEEDERMobile home feeder: three aluminium alloy conductors and an insulated ground, XLPE insulated (USE-2 / RHH / RHW-2), direct burial600 V, 90 C wet or dry
ACArmored cable (BX): insulated conductors with a 16 AWG aluminium bond wire in interlocked steel armour, no outer jacket600 V, 90 C conductors (AC-90 / ACHH)
MCMetal-clad cable: insulated conductors and a green ground in interlocked metal armour600 V, 90 C conductors
MC-HLMetal-clad cable for hazardous locations: continuous corrugated aluminium sheath and PVC jacket600 V or 1000 V, 90 C (XHHW-2)
TCTray cable: multiconductor power or control cable for cable trays600 V, 90 C dry, 75 C wet
TC-ERTray cable, exposed run: may run outside tray or conduit up to 6 ft, supported and secured600 V, 90 C dry, 75 C wet
TC-ER-HLTray cable, exposed run, hazardous locations600 V, 90 C dry, 75 C wet
ITCInstrumentation tray cable, shielded pairs, for circuits up to 150 V and 5 A300 V
ITC-ERInstrumentation tray cable, exposed run300 V
PLTCPower-limited tray cable, shielded pairs, 300 V300 V
PLTC-ERPower-limited tray cable, exposed run300 V
MV-90Medium-voltage shielded power cable, 90 C2 kV to 35 kV, 90 C
MV-105Medium-voltage shielded power cable, 105 C2 kV to 35 kV, 105 C
AEIC-CS9High voltage XLPE power cable, single conductor, 69 to 345 kV, as the makers print its legend (size, metal, wall in mils, class)69, 115, 138, 161, 230 and 345 kV, 90 C
SStandard thermoset flexible cord600 V, 90 C
SOStandard thermoset flexible cord, oil-resistant600 V, 90 C
SOOStandard thermoset flexible cord, oil-resistant600 V, 90 C
SOWStandard thermoset flexible cord, oil-resistant, weather-resistant600 V, 90 C
SOOWStandard thermoset flexible cord, oil-resistant, weather-resistant600 V, 90 C
SJJunior thermoset flexible cord300 V, 90 C
SJOJunior thermoset flexible cord, oil-resistant300 V, 90 C
SJOWJunior thermoset flexible cord, oil-resistant, weather-resistant300 V, 90 C
SJOOWJunior thermoset flexible cord, oil-resistant, weather-resistant300 V, 90 C
SJTJunior thermoplastic flexible cord300 V, 60 to 105 C
SJTWJunior thermoplastic flexible cord, weather-resistant300 V, 60 to 105 C
SJTOJunior thermoplastic flexible cord, oil-resistant300 V, 60 to 105 C
SJTOWJunior thermoplastic flexible cord, oil-resistant, weather-resistant300 V, 60 to 105 C
SJTOOWJunior thermoplastic flexible cord, oil-resistant, weather-resistant300 V, 60 to 105 C
STStandard thermoplastic flexible cord600 V, 60 to 105 C
STWStandard thermoplastic flexible cord, weather-resistant600 V, 60 to 105 C
STOStandard thermoplastic flexible cord, oil-resistant600 V, 60 to 105 C
STOWStandard thermoplastic flexible cord, oil-resistant, weather-resistant600 V, 60 to 105 C
STOOWStandard thermoplastic flexible cord, oil-resistant, weather-resistant600 V, 60 to 105 C
SEOWStandard elastomer flexible cord, oil-resistant, weather-resistant600 V, 105 C
SEOOWStandard elastomer flexible cord, oil-resistant, weather-resistant600 V, 105 C
SJEOOWJunior elastomer flexible cord, oil-resistant, weather-resistant300 V, 105 C
SPT-1Parallel thermoplastic lamp cord, insulation class 1300 V, 60 to 105 C (UNVERIFIED)
SPT-2Parallel thermoplastic lamp cord, insulation class 2300 V, 60 to 105 C (UNVERIFIED)
SPT-3Parallel thermoplastic lamp cord, insulation class 3300 V, 60 to 105 C (UNVERIFIED)
SPTSPT: parallel thermoplastic (zip) cord, two or three conductors moulded side by side in PVC, no jacket; the insulation class (SPT-1, SPT-2 or SPT-3) not given300 V; 60 C or 105 C by listing (Southwire, Cerrowire, AWC)
SVTVacuum-cleaner (service) thermoplastic cord, PVC jacket, 300 V300 V, 60 to 105 C
SVTOVacuum-cleaner thermoplastic cord with an oil-resistant PVC jacket, 300 V300 V, 60 to 105 C
HPNHeater cord, parallel, neoprene (UNVERIFIED expansion)300 V, 90 C (UNVERIFIED)
TYPE WPortable power cable, 2 kV, tinned copper, EPDM insulation, extra-hard usage2000 V, 90 C
TYPE GPortable power cable with grounding conductors, 2 kV, mining and industrial (UNVERIFIED)2000 V, 90 C (UNVERIFIED)
G-GCPortable power cable with grounding and a ground-check conductor (UNVERIFIED)2000 V, 90 C (UNVERIFIED)
DLODiesel locomotive cable: tinned flexible copper, EPR insulation, CPE jacket, single conductor2000 V, 90 C
PV WIREPhotovoltaic wire: stranded copper, XLP insulation, sunlight resistant600 V or 1000 V or 2000 V, 90 C wet or dry
CMCommunications cable, general purpose300 V, 75 C
CMPCommunications cable, plenum rated (low smoke; FEP insulation on 4-pair data cable, low-smoke PVC on 2-conductor cable)300 V, 60 to 150 C by product (75 C most common)
CMRCommunications cable, riser rated (vertical shafts, UL 1666)300 V, 60 or 75 C by product
CMGCommunications cable, general purpose (FT4 vertical flame test)300 V, 60 C
CMXCommunications cable, limited use (residential and in raceway, outdoor-rated types)300 V, 60 to 75 C
CL2Class 2 remote-control and signalling cableClass 2 power-limited, no voltage rating (UL 13 1.2)
THERMOSTAT WIREThermostat wire: Class 2 control cable, solid bare copper conductors in a PVC jacket150 V, Class 2 power-limited (as two makers print it)
LANDSCAPE WIRELow voltage landscape lighting wire: underground low-energy circuit cable, two stranded copper conductors in one flat PVC layer150 V (UL), 30 V (CSA LVLL); -20 to 60 C; direct burial
CL2RClass 2 remote-control and signalling cable, riserClass 2 power-limited, no voltage rating (UL 13 1.2)
CL2PClass 2 remote-control and signalling cable, plenumClass 2 power-limited, no voltage rating (UL 13 1.2)
CL2XClass 2 remote-control and signalling cable, limited useClass 2 power-limited, no voltage rating (UL 13 1.2)
CL3Class 3 remote-control and signalling cable300 V, Class 3 power-limited (UL 13 1.2: rated 300 V, not so marked)
CL3RClass 3 remote-control and signalling cable, riser300 V, Class 3 power-limited (UL 13 1.2: rated 300 V, not so marked)
CL3PClass 3 remote-control and signalling cable, plenum300 V, Class 3 power-limited (UL 13 1.2: rated 300 V, not so marked)
CL3XClass 3 remote-control and signalling cable, limited use300 V, Class 3 power-limited (UL 13 1.2: rated 300 V, not so marked)
FPLFire-alarm power-limited cable300 V, 75 C
FPLRFire-alarm power-limited cable, riser (UL 1666)300 V, 75 C
FPLPFire-alarm power-limited cable, plenum (UL 910, low smoke)300 V, 75 C
OFNOptical fibre cable, nonconductive generalDielectric
OFNGOptical fibre cable, nonconductive, general purposeDielectric
OFNROptical fibre cable, nonconductive, riserDielectric
OFNPOptical fibre cable, nonconductive, plenumDielectric
OFCOptical fibre cable, conductive generalFibre with metallic strength member
OFCROptical fibre cable, conductive, riserFibre with metallic strength member
OFCPOptical fibre cable, conductive, plenumFibre with metallic strength member
CAT5ECategory 5e unshielded or shielded twisted-pair data cable, 4 pairs, 24 AWGup to 100 MHz, 1 Gbit/s
CAT6Category 6 twisted-pair data cable, 4 pairs, 23 AWGup to 250 MHz
CAT6ACategory 6A augmented twisted-pair data cable, 4 pairsup to 500 MHz (UNVERIFIED)
AWM 1007UL AWM style 1007: single-conductor PVC appliance wiring material (hook-up wire)300 V a.c., 80 C, 32 to 16 AWG
AWM 1015UL AWM style 1015: single-conductor PVC appliance wiring material (hook-up wire)600 V a.c. or 750 V d.c., 80 / 90 / 105 C, 30 AWG to 2000 kcmil
AWM 2464UL AWM style 2464: multi-conductor equipment cable, singles or twisted pairs, often foil and braid screened300 V a.c., 80 C
AWM 2517UL AWM style 2517: multi-conductor equipment cable, singles or twisted pairs, often foil and braid screened300 V a.c., 105 C
AWM 2919UL AWM style 2919: multi-conductor equipment cable, singles or twisted pairs, often foil and braid screened30 V a.c., 80 C
AWM 20276UL AWM style 20276: multi-conductor equipment cable, singles or twisted pairs, often foil and braid screened30 V a.c., 60 or 80 C
VFDVariable frequency drive cable, Type TC-ER: three XLPE cores, three symmetrical grounds, overall screen1000 V or 2000 V, 90 C wet and dry
TC-ER-JPTray cable, exposed run, joist-pull tested (may be pulled through joists in one- and two-family dwellings)600 V, 90 C dry, 75 C wet
CATVCommunity antenna television coaxial cable, general use75 ohm coaxial (RG-6 / RG-59 builds)
CATVRCommunity antenna television coaxial cable, riser (UL 1666)75 ohm coaxial (RG-6 / RG-59 builds)
CATVPCommunity antenna television coaxial cable, plenum (NFPA 262)75 ohm coaxial (RG-6 / RG-59 builds)
CATVXCommunity antenna television coaxial cable, limited use (dwellings, raceway)75 ohm coaxial (RG-6 / RG-59 builds)
CMP-LPCommunications cable, plenum rated (low smoke, FEP insulation), limited power (LP): marked with the current per conductor for PoE300 V, 75 C
CMR-LPCommunications cable, riser rated (vertical shafts, UL 1666), limited power (LP): marked with the current per conductor for PoE300 V, 75 C
CMG-LPCommunications cable, general purpose (same listing level as CM), limited power (LP): marked with the current per conductor for PoE300 V, 60 to 75 C
CM-LPCommunications cable, general purpose, limited power (LP): marked with the current per conductor for PoE300 V, 60 to 75 C
OFCGOptical fibre cable, conductive, general purposeFibre with metallic strength member
NPLFNon-power-limited fire alarm cable, general600 V (typical)
NPLFRNon-power-limited fire alarm cable, riser600 V (typical)
NPLFPNon-power-limited fire alarm cable, plenum600 V (typical)
ITC-HLInstrumentation tray cable, shielded pairs, for circuits up to 150 V and 5 A, hazardous location: continuously welded corrugated aluminium sheath and a PVC jacket300 V
PLTC-HLPower-limited tray cable, shielded pairs, 300 V, hazardous location: continuously welded corrugated aluminium sheath and a PVC jacket300 V
CMUCCommunications under-carpet cable: flat conductors for use under carpet squarescommunications
SHD-GCSHD-GC: shielded round portable mine power cable, three EPR phase cores each under a tinned copper / textile braid shield, two grounding conductors and a yellow ground-check conductor, reinforced CPE jacket2000 V to 35000 V classes, 90 C (Prysmian); 5 kV, 8 kV, 15 kV (Priority Wire)
SHD-CGCSHD-CGC: SHD-GC with an extensible (centre) ground-check conductor and three grounding conductors, 2000 to 5000 V2000 V and 5000 V, 90 C (Prysmian)
MP-GCMP-GC: mine power feeder cable with ground check, three shielded EPR (or XLP) cores with copper tape shields, two grounding conductors and a ground-check conductor, CPE (or PVC) jacket, 5 to 35 kV, for permanent installation5000 V to 35000 V, 90 C, 100 % insulation level (Prysmian, Tele-Fonika)
ALPETHALPETH: aerial telephone cable with an aluminium shield and a polyethylene jackettelephone
ALVYNALVYN: indoor riser-rated telephone cable with an aluminium shield and a vinyl (PVC) jackettelephone
ASPASP: filled direct-burial telephone cable for rodent areas, corrugated aluminium shield, corrugated steel tape, flooding compound, polyethylene jackettelephone
PICPIC: plastic-insulated telephone cable (a general term for any type)telephone

Merkinger ved siden av navnet

Ord og merkinger som dekoderen leser ved siden av et typenavn i dette systemet: hver av dem legger til en egenskap på typen den står ved siden av.

MerkingBetydningSkrives som
100%Insulation level 100 %: ground faults cleared within one minute (ICEA)100% 100 % 100% INSULATION 100 PERCENT
133%Insulation level 133 %: ground faults cleared within one hour (ICEA)133% 133 % 133% INSULATION 133 PERCENT
173%Insulation level 173 %: ground faults may last longer than one hour (ICEA)173% 173 % 173% INSULATION
JCNJacketed concentric neutral: copper wire neutral under an overall jacketJCN

Vanlige spørsmål

Hva er kabelen THW?

THW: Thermoplastic heat- and moisture-resistant building wire, 75 C. Merkedata: 600 V, 75 C dry and wet. Standard: UL 83; NEC Article 310. Navnet leses: T (Thermoplastic (PVC) insulation) + H (Heat resistant, 75 C (one H)) + W (Approved for wet locations).

Hva er kabelen AEIC-CS9?

AEIC-CS9: High voltage XLPE power cable, single conductor, 69 to 345 kV, as the makers print its legend (size, metal, wall in mils, class). Merkedata: 69, 115, 138, 161, 230 and 345 kV, 90 C. Standard: AEIC CS9-06 (1st edition, 2006); ICEA S-108-720.

Hva er forskjellen mellom THHN og TFFN?

THHN: Thermoplastic high heat-resistant nylon-coated building wire, 600 V, 90 C dry and damp locations. TFFN: Thermoplastic flexible fixture wire, nylon-coated, 600 V, 90 C. Navnene skiller seg i: THHN: HH (High heat resistant, 90 C (one H means 75 C)); TFFN: FF (Flexible fixture (stranded) wire).

NEC / UL (USA): hva betyr T i et kabelnavn?

T har mer enn én betydning, avhengig av typen: Thermoplastic (PVC) insulation (TW, THW, THHW, THWN +6); Thermoplastic (PVC) insulation and jacket (SJT, SJTW, SJTO, SJTOW +6); Thermoplastic (PVC) (SPT-1, SPT-2, SPT-3, SPT +1).

NEC / UL (USA): hva betyr 100% ved siden av et kabelnavn?

100%: Insulation level 100 %: ground faults cleared within one minute (ICEA). Skrives som 100%, 100 %, 100% INSULATION, 100 PERCENT.

Hva er kabelen THHN?

THHN: Thermoplastic high heat-resistant nylon-coated building wire. Merkedata: 600 V, 90 C dry and damp locations. Standard: UL 83; NEC Article 310. Navnet leses: T (Thermoplastic (PVC) insulation) + HH (High heat resistant, 90 C (one H means 75 C)) + N (Nylon outer covering).

Typetabellens kilder

Standarder som nevnes i tabellen

  • UL 83
  • NEC Article 310
  • UL 1063
  • NEC Article 670
  • UL 44
  • UL 854
  • NEC Article 338
  • NEC Table 310.104(A)
  • UL 66
  • NEC Article 402
  • UL 719
  • NEC Article 334
  • UL 493
  • NEC Article 340
  • ICEA / NEMA WC 70
  • UL 854 (USE-2)
  • UL 4
  • NEC Article 320
  • UL 1569
  • NEC Article 330
  • UL 2225 (UNVERIFIED)
  • NEC Articles 330 and 501 to 505
  • UL 1277
  • NEC Article 336
  • UL 2250
  • NEC Article 727
  • UL 13
  • NEC Article 725
  • UL 1072
  • NEC Article 311
  • AEIC CS9-06 (1st edition, 2006)
  • ICEA S-108-720
  • UL 62
  • NEC Article 400, Table 400.4
  • NEC Table 400.4
  • UL Subject 1680
  • CSA C22.2 No. 96
  • NEC Article 400 (also 520, 525, 530)
  • UL 1650
  • NEC Article 400
  • UL RHH/RHW-2 (600 V and 2000 V)
  • ICEA S-95-658 / NEMA WC 70
  • AAR RP-586 and RP-588
  • CSA RW90 and RW90-TC
  • UL 4703
  • NEC Article 690
  • UL 444
  • NEC Article 800
  • NEC 800.179(A)
  • NEC 800.179(B)
  • UL 444 / CSA C22.2 No. 214
  • UL 13 (power-limited circuit cable)
  • NEC Article 725, Class 2
  • UL 1493 (underground low-energy circuit cable for outdoor lighting)
  • CSA LVLL
  • UL 1424
  • NEC Article 760
  • UL 1651
  • NEC Article 770
  • ANSI/TIA-568 Category 5e
  • ANSI/TIA-568 Category 6
  • ANSI/TIA-568 Category 6A
  • UL 758 (AWM style page)
  • UL 1277 TC-ER
  • UL 1655
  • NEC Article 820 (820.179)
  • UL 1425
  • NEC Article 760 Part II
  • ICEA S-75-381 / NEMA WC 58
  • MSHA accepted
  • MSHA P-7K-102045-2
  • MSHA
  • REA / RUS telephone cable practice (General Cable glossary)
  • General Cable glossary

Dokumenter og sider opplysningene er hentet fra

Hentet fra dette nettstedets typetabell, med kildene ovenfor. Kontroller produsentens datablad før du spesifiserer en kabel.

Alle typer i NEC / UL (USA) · Dekod din egen typebetegnelse