# ZWH

**ZWH** er en kabelbetegnelse etter [BIS-typebetegnelser (India)](https://thecablecode.com/no/standards/bis-india): Z = XL-HFFR-isolasjon, tverrbundet, halogenfri, flammehemmende (IS 17505 (Part 1) cl. 6, 19.4); Z i IS 7098 (Part 1) og IS 17048 er termoplastisk; W = Armering av galvaniserte runde ståltråder (IS 17505 (Part 1) cl. 8, 15.2, 19.4); H = Halogenfri ytterkappe HFS-TP 90 eller HFS-XL 90 (IS 17505 (Part 1) cl. 9, 19.4); ZWH = ZWH: fire survival cable (IS 17505 (Part 1)): copper conductors under glass mica tape, XL-HFFR (crosslinked halogen-free flame-retardant) insulation, extruded inner sheath, galvanised round steel wire armour, zero halogen (HFS) outer sheath. Up to and including 1100 V a.c. and 1500 V d.c.; 90 C normal, 250 C short circuit (cl. 1); fire survival category F3, F30, F60 or F120 (cl. 3.5, Annex E), printed as "FS Cable" with the category (cl. 19.2) and in the code (cl. 19.4). IS 17505 (Part 1):2021, cable code cl. 19.4.

1 kodesystem gjenkjenner denne betegnelsen

**Standarder bak disse verdiene:**

- IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
- IEC 60502-2:2014 (edition 3.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
- IEC 60228:2023 (edition 4.0): Conductors of insulated cables

## BIS-typebetegnelser (India)

| Symbol | Betydning |
|---|---|
| `Z` | XL-HFFR-isolasjon, tverrbundet, halogenfri, flammehemmende (IS 17505 (Part 1) cl. 6, 19.4); Z i IS 7098 (Part 1) og IS 17048 er termoplastisk |
| `W` | Armering av galvaniserte runde ståltråder (IS 17505 (Part 1) cl. 8, 15.2, 19.4) |
| `H` | Halogenfri ytterkappe HFS-TP 90 eller HFS-XL 90 (IS 17505 (Part 1) cl. 9, 19.4) |
| `ZWH` | ZWH: fire survival cable (IS 17505 (Part 1)): copper conductors under glass mica tape, XL-HFFR (crosslinked halogen-free flame-retardant) insulation, extruded inner sheath, galvanised round steel wire armour, zero halogen (HFS) outer sheath. Up to and including 1100 V a.c. and 1500 V d.c.; 90 C normal, 250 C short circuit (cl. 1); fire survival category F3, F30, F60 or F120 (cl. 3.5, Annex E), printed as "FS Cable" with the category (cl. 19.2) and in the code (cl. 19.4). IS 17505 (Part 1):2021, cable code cl. 19.4 |

- [Kabel ZWH: betydning, oppbygging og 3D-visning](https://thecablecode.com/no/c/ZWH)
- [Konstruer ZWH i kabeldesigneren: lag, diameter og vekt](https://thecablecode.com/no/design/ZWH)
- [Flere BIS-typebetegnelser (India) betegnelser](https://thecablecode.com/no/standards/bis-india)

## Beslektede kabler

- [TWH](https://thecablecode.com/no/c/TWH)
- [ZWWH](https://thecablecode.com/no/c/ZWWH)
- [ZWaH](https://thecablecode.com/no/c/ZWaH)