title: "yry cable: meaning, layers and 3D view"
code: "yry"
url: https://thecablecode.com/c/yry
language: en
---

# yry

**yry** is a [DIN VDE 0271/0276 power cables (Germany)](https://thecablecode.com/standards/din-vde-0271-0276) cable designation: Y = Polyvinyl Chloride (PVC); R = Round Steel Wire; Y = Polyvinyl Chloride (PVC).

5 coding systems recognise this code

**Standards behind these values:**

- IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
- IEC 60502-2:2014 (edition 3.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
- IEC 60228:2023 (edition 4.0): Conductors of insulated cables

## DIN VDE 0271/0276 power cables (Germany)

| Symbol | Meaning |
|---|---|
| `Y` | Polyvinyl Chloride (PVC) |
| `R` | Round Steel Wire |
| `Y` | Polyvinyl Chloride (PVC) |

[How to read a DIN VDE 0271/0276 power cables (Germany) cable code](https://thecablecode.com/guides/din-vde-0271-0276)

## China (GB / JB/T / MT cable model codes)

| Symbol | Meaning |
|---|---|
| `Y` | Polyethylene (PE) Or Polyolefin |
| `R` | Flexible Cable |
| `Y` | Polyethylene (PE) Or Polyolefin |

[How to read a China (GB / JB/T / MT cable model codes) cable code](https://thecablecode.com/guides/china)

## ZN-TF-500 (Poland, MV cables)

| Symbol | Meaning |
|---|---|
| `Y` | Polyvinyl Chloride (PVC) Sheath |
| `R` | Radially Sealed (Al/Copolymer Tape Bonded To The Sheath) |
| `Y` | Polyvinyl Chloride (PVC) Sheath |

[How to read a ZN-TF-500 (Poland, MV cables) cable code](https://thecablecode.com/guides/zn-tf-500)

## India (IS 1554 / IS 7098 cable code)

| Symbol | Meaning |
|---|---|
| `Y` | Polyvinyl Chloride (PVC) |
| `R` | Elastomer (Rubber) Insulation Or Outer Sheath |
| `Y` | Polyvinyl Chloride (PVC) |

[How to read a India (IS 1554 / IS 7098 cable code) cable code](https://thecablecode.com/guides/is-1554)

## NEN 3207 / KEMA (Netherlands)

| Symbol | Meaning |
|---|---|
| `Y` | Cross-Linked Polyethylene (XLPE) |
| `R` | Round Conductor |
| `Y` | Cross-Linked Polyethylene (XLPE) |

[How to read a NEN 3207 / KEMA (Netherlands) cable code](https://thecablecode.com/guides/kema)

## yry: equivalents in other countries

Shown for 4x16 0.6/1 kV. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.

| Country | Standard | Name in that country | Verdict | Differences |
|---|---|---|---|---|
| Germany | HD 603 3-G (DIN VDE 0276-603) | NYYRY 4x16 RM 0,6/1 kV | **Close** | this cable as built misses 1 of its rules |
| India | IS 1554 (Part 1) | [YWY](https://thecablecode.com/c/YWY) 4x16 1100 V | **Close** | rated 0.635/1.1 kV (same Um 1.2 kV); routine voltage test 3 kV a.c., 5 min (this cable 3.5 kV; IS 1554 (Part 1) cl. 16.2, IS 7098 (Part 1) cl. 17.2.1, IEC 60502-1 Table 11); Inner covering / bedding 1 → 0.3 mm; Sheath 1.2 → 1.4 mm |

Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.

- [yry cable: meaning, layers and 3D view](https://thecablecode.com/c/yry)
- [Design yry in the cable designer: layers, diameter and weight](https://thecablecode.com/design/yry)
- [More DIN VDE 0271/0276 power cables (Germany) designations](https://thecablecode.com/standards/din-vde-0271-0276)

## Related cables

- [NYRY](https://thecablecode.com/c/NYRY)
- [2XYRY 4](https://thecablecode.com/c/2XYRY%204)
- [N2XSEYRY](https://thecablecode.com/c/N2XSEYRY)
- [NA2XSEYRY](https://thecablecode.com/c/NA2XSEYRY)
- [N2XSEYRYBY](https://thecablecode.com/c/N2XSEYRYBY)