title: "YVZ2V-R cable: meaning, layers and 3D view"
code: "YVZ2V-R"
url: https://thecablecode.com/c/YVZ2V-R
language: en
---

# YVZ2V-R

**YVZ2V-R** is a [TS 621 / TSE (Turkey)](https://thecablecode.com/standards/ts-621) cable designation: Y = Underground Heavy-Duty Cable For Fixed Installation (Y Cable Family, TS 212); V = Polyvinyl Chloride (PVC); Z2 = Round Steel Wire Armour; V = Polyvinyl Chloride (PVC); -R = Round Stranded Conductor (Class 2).

2 coding systems recognise this code

**Standards behind these values:**

- IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
- IEC 60502-2:2014 (edition 3.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
- IEC 60228:2023 (edition 4.0): Conductors of insulated cables

## TS 621 / TSE (Turkey)

| Symbol | Meaning |
|---|---|
| `Y` | Underground Heavy-Duty Cable For Fixed Installation (Y Cable Family, TS 212) |
| `V` | Polyvinyl Chloride (PVC) |
| `Z2` | Round Steel Wire Armour |
| `V` | Polyvinyl Chloride (PVC) |
| `-R` | Round Stranded Conductor (Class 2) |

[How to read a TS 621 / TSE (Turkey) cable code](https://thecablecode.com/guides/ts-621)

## HAR: HD 361 harmonised designation (CENELEC)

| Symbol | Meaning |
|---|---|
| `Y` | Turkish TS Type For Medium And Heavy Operating Conditions (e.g. YXC7V-R) |
| `V` | Polyvinyl Chloride (PVC) |
| `Z2` | Round Steel Wire |
| `V` | Polyvinyl Chloride (PVC) |
| `-R` | Multi-Wire, Round-Section, Class 2 |

[How to read a HAR: HD 361 harmonised designation (CENELEC) cable code](https://thecablecode.com/guides/har)

## YVZ2V-R: equivalents in other countries

Shown for 4x16 0.6/1 kV. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.

| Country | Standard | Name in that country | Verdict | Differences |
|---|---|---|---|---|
| Germany | HD 603 3-G (DIN VDE 0276-603) | NYYRY 4x16 RM 0,6/1 kV | **Close** | this cable as built misses 1 of its rules |
| India | IS 1554 (Part 1) | [YWY](https://thecablecode.com/c/YWY) 4x16 1100 V | **Close** | rated 0.635/1.1 kV (same Um 1.2 kV); routine voltage test 3 kV a.c., 5 min (this cable 3.5 kV; IS 1554 (Part 1) cl. 16.2, IS 7098 (Part 1) cl. 17.2.1, IEC 60502-1 Table 11); Inner covering / bedding 1 → 0.3 mm; Sheath 1.2 → 1.4 mm |

Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.

- [YVZ2V-R cable: meaning, layers and 3D view](https://thecablecode.com/c/YVZ2V-R)
- [Design YVZ2V-R in the cable designer: layers, diameter and weight](https://thecablecode.com/design/YVZ2V-R)
- [More TS 621 / TSE (Turkey) designations](https://thecablecode.com/standards/ts-621)

## Related cables

- [YXZ2V-R](https://thecablecode.com/c/YXZ2V-R)
- [YVV-R](https://thecablecode.com/c/YVV-R)