title: "YVV cable: meaning, layers and 3D view"
code: "YVV"
url: https://thecablecode.com/c/YVV
language: en
---

# YVV

**YVV** is a [TS 621 / TSE (Turkey)](https://thecablecode.com/standards/ts-621) cable designation: Y = Underground Heavy-Duty Cable For Fixed Installation (Y Cable Family, TS 212); V = Polyvinyl Chloride (PVC); V = Polyvinyl Chloride (PVC).

5 coding systems recognise this code

**Standards behind these values:**

- IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
- IEC 60228:2023 (edition 4.0): Conductors of insulated cables

## TS 621 / TSE (Turkey)

| Symbol | Meaning |
|---|---|
| `Y` | Underground Heavy-Duty Cable For Fixed Installation (Y Cable Family, TS 212) |
| `V` | Polyvinyl Chloride (PVC) |
| `V` | Polyvinyl Chloride (PVC) |

[How to read a TS 621 / TSE (Turkey) cable code](https://thecablecode.com/guides/ts-621)

## HAR: HD 361 harmonised designation (CENELEC)

| Symbol | Meaning |
|---|---|
| `Y` | Turkish TS Type For Medium And Heavy Operating Conditions (e.g. YXC7V-R) |
| `V` | Polyvinyl Chloride (PVC) |
| `V` | Polyvinyl Chloride (PVC) |

[How to read a HAR: HD 361 harmonised designation (CENELEC) cable code](https://thecablecode.com/guides/har)

## DIN VDE 0250 cords, control and special cables (Germany)

| Symbol | Meaning |
|---|---|
| `Y` | Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General |
| `V` | Wiring Cable (Verdrahtungsleitung); (V) In Mining Cables: Reinforced |
| `V` | Wiring Cable (Verdrahtungsleitung); (V) In Mining Cables: Reinforced |

[How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code](https://thecablecode.com/guides/old-vde-0250)

## China (GB / JB/T / MT cable model codes)

| Symbol | Meaning |
|---|---|
| `Y` | Polyethylene (PE) Or Polyolefin |
| `V` | Polyvinyl Chloride (PVC) |
| `V` | Polyvinyl Chloride (PVC) |

[How to read a China (GB / JB/T / MT cable model codes) cable code](https://thecablecode.com/guides/china)

## NEN 3207 / KEMA (Netherlands)

| Symbol | Meaning |
|---|---|
| `Y` | Cross-Linked Polyethylene (XLPE) |
| `V` | Polyvinyl Chloride (PVC) |
| `V` | Polyvinyl Chloride (PVC) |

[How to read a NEN 3207 / KEMA (Netherlands) cable code](https://thecablecode.com/guides/kema)

## YVV: equivalents in other countries

Shown for 1x16 0.6/1 kV. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.

| Country | Standard | Name in that country | Verdict | Differences |
|---|---|---|---|---|
| Germany | HD 603 3-G (DIN VDE 0276-603) | [NYY](https://thecablecode.com/c/NYY) 1x16 RM 0,6/1 kV | **Close** | Sheath 1.4 → 1.8 mm; Overall diameter 9.7 → 10.5 mm; this cable as built misses 2 of its rules |
| India | IS 1554 (Part 1) | [YY](https://thecablecode.com/c/YY) 1x16 1100 V (the code letters of IS 1554 (Part 1):1988 cl. 17.3) | **Close** | rated 0.635/1.1 kV (same Um 1.2 kV); routine voltage test 3 kV a.c., 5 min (this cable 3.5 kV; IS 1554 (Part 1) cl. 16.2, IS 7098 (Part 1) cl. 17.2.1, IEC 60502-1 Table 11); Sheath 1.4 → 1.8 mm; Overall diameter 9.7 → 10.5 mm; this cable as built misses 1 of its rules |

Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.

- [YVV cable: meaning, layers and 3D view](https://thecablecode.com/c/YVV)
- [Design YVV in the cable designer: layers, diameter and weight](https://thecablecode.com/design/YVV)
- [More TS 621 / TSE (Turkey) designations](https://thecablecode.com/standards/ts-621)

## Related cables

- [YVV-R](https://thecablecode.com/c/YVV-R)
- [YVV-A](https://thecablecode.com/c/YVV-A)
- [YVV-U](https://thecablecode.com/c/YVV-U)