title: "YKY cable: meaning, layers and 3D view"
code: "YKY"
url: https://thecablecode.com/c/YKY
language: en
---

# YKY

**YKY** is a [PN (Poland)](https://thecablecode.com/standards/pn) cable designation: Y = PVC sheath; the sheath letter comes first in Polish names; K = kabel: power cable family (not a copper letter); Y = PVC insulation; YKY = YKY: copper power cable, PVC insulation and PVC sheath, 0,6/1 kV (closest VDE: NYY-O, with żo NYY-J). 0,6/1 kV (3,6/6 kV also listed). PN-93/E-90400; PN-93/E-90401; PN-HD 603 S1:2006/A3:2009 (as printed in the Elpar catalogue).

1 coding system recognises this code

**Standards behind these values:**

- IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
- IEC 60228:2023 (edition 4.0): Conductors of insulated cables

## PN (Poland)

| Symbol | Meaning |
|---|---|
| `Y` | PVC sheath; the sheath letter comes first in Polish names |
| `K` | kabel: power cable family (not a copper letter) |
| `Y` | PVC insulation |
| `YKY` | YKY: copper power cable, PVC insulation and PVC sheath, 0,6/1 kV (closest VDE: NYY-O, with żo NYY-J). 0,6/1 kV (3,6/6 kV also listed). PN-93/E-90400; PN-93/E-90401; PN-HD 603 S1:2006/A3:2009 (as printed in the Elpar catalogue) |

## YKY: equivalents in other countries

Shown for 1x16 0.6/1 kV. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.

| Country | Standard | Name in that country | Verdict | Differences |
|---|---|---|---|---|
| Germany | HD 603 3-G (DIN VDE 0276-603) | [NYY](https://thecablecode.com/c/NYY) 1x16 RM 0,6/1 kV | **Close** | Sheath 1.4 → 1.8 mm; Overall diameter 9.7 → 10.5 mm; this cable as built misses 2 of its rules |
| India | IS 1554 (Part 1) | [YY](https://thecablecode.com/c/YY) 1x16 1100 V (the code letters of IS 1554 (Part 1):1988 cl. 17.3) | **Close** | rated 0.635/1.1 kV (same Um 1.2 kV); routine voltage test 3 kV a.c., 5 min (this cable 3.5 kV; IS 1554 (Part 1) cl. 16.2, IS 7098 (Part 1) cl. 17.2.1, IEC 60502-1 Table 11); Sheath 1.4 → 1.8 mm; Overall diameter 9.7 → 10.5 mm; this cable as built misses 1 of its rules |

Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.

- [YKY cable: meaning, layers and 3D view](https://thecablecode.com/c/YKY)
- [Design YKY in the cable designer: layers, diameter and weight](https://thecablecode.com/design/YKY)
- [More PN (Poland) designations](https://thecablecode.com/standards/pn)

## Related cables

- [YKYY](https://thecablecode.com/c/YKYY)
- [CYKY](https://thecablecode.com/c/CYKY)
- [AYKY](https://thecablecode.com/c/AYKY)
- [1-CYKY](https://thecablecode.com/c/1-CYKY)
- [NYKY-J](https://thecablecode.com/c/NYKY-J)
- [1-AYKY](https://thecablecode.com/c/1-AYKY)
- [CYKYZ](https://thecablecode.com/c/CYKYZ)
- [AYKYZ](https://thecablecode.com/c/AYKYZ)
- [YKYFTY](https://thecablecode.com/c/YKYFTY)
- [YKYFOY](https://thecablecode.com/c/YKYFOY)