title: "THW cable: meaning, layers and 3D view"
code: "THW"
url: https://thecablecode.com/c/THW
language: en
---

# THW

**THW** is a [NEC / UL (USA)](https://thecablecode.com/standards/nec-ul) cable designation: T = Thermoplastic (PVC) insulation; H = Heat resistant, 75 C (one H); W = Approved for wet locations; THW = Thermoplastic heat- and moisture-resistant building wire, 75 C. 600 V, 75 C dry and wet. UL 83; NEC Article 310.

4 coding systems recognise this code

**Standards behind these values:**

- UL 83 (edition 16): Thermoplastic-Insulated Wires and Cables

## NEC / UL (USA)

| Symbol | Meaning |
|---|---|
| `T` | Thermoplastic (PVC) insulation |
| `H` | Heat resistant, 75 C (one H) |
| `W` | Approved for wet locations |
| `THW` | Thermoplastic heat- and moisture-resistant building wire, 75 C. 600 V, 75 C dry and wet. UL 83; NEC Article 310 |

## TIS 11 type names (Thailand)

| Symbol | Meaning |
|---|---|
| `THW` | THW: Thai name of the single-core PVC-insulated building wire 60227 IEC 01 (TIS 11 Part 3), printed "THW IEC01"; not the US THW |
| `THW` | THW (Thailand): single-core PVC-insulated copper building wire, 60227 IEC 01. 450/750 V, 70 C (Thai Cable Wires; Yazaki listing). TIS 11 Part 3-2553 (60227 IEC 01) |

## NEC Article 310 (US building wire, NFPA 70)

| Symbol | Meaning |
|---|---|
| `T` | Thermoplastic Insulation |
| `H` | 75°C Insulation |
| `W` | Moisture Resistant |

[How to read a NEC Article 310 (US building wire, NFPA 70) cable code](https://thecablecode.com/guides/nec-310)

## NEC Article 400 (US flexible cords, NFPA 70 / UL 62)

| Symbol | Meaning |
|---|---|
| `T` | Thermoplastic Insulation And Jacket |
| `H` | Heater Cord |
| `W` | Suitable For Use In Wet Locations And Sunlight Resistant |

[How to read a NEC Article 400 (US flexible cords, NFPA 70 / UL 62) cable code](https://thecablecode.com/guides/nec-400)

## THW: equivalents in other countries

Shown for 1x3.31 600 V. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.

| Country | Standard | Name in that country | Verdict | Differences |
|---|---|---|---|---|
| International (IEC) | IEC 60502 | no letters for this build | **Close** | Insulation 0.76 → 1 mm; Overall diameter 3.79 → 4.27 mm |

Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.

- [THW cable: meaning, layers and 3D view](https://thecablecode.com/c/THW)
- [Design THW in the cable designer: layers, diameter and weight](https://thecablecode.com/design/THW)
- [More NEC / UL (USA) designations](https://thecablecode.com/standards/nec-ul)

## Related cables

- [THW-2](https://thecablecode.com/c/THW-2)
- [THW-1](https://thecablecode.com/c/THW-1)
- [THWX](https://thecablecode.com/c/THWX)
- [THWN](https://thecablecode.com/c/THWN)
- [THW(F)](https://thecablecode.com/c/THW(F))
- [THW-A](https://thecablecode.com/c/THW-A)
- [THWst](https://thecablecode.com/c/THWst)
- [THWN-2](https://thecablecode.com/c/THWN-2)
- [THW-LS](https://thecablecode.com/c/THW-LS)
- [THW-90](https://thecablecode.com/c/THW-90)
- [THWR7E](https://thecablecode.com/c/THWR7E)