title: "NYY-RM cable: meaning, layers and 3D view"
code: "NYY-RM"
url: https://thecablecode.com/c/NYY-RM
language: en
---

# NYY-RM

**NYY-RM** is a [DIN VDE 0271/0276 power cables (Germany)](https://thecablecode.com/standards/din-vde-0271-0276) cable designation: N = VDE Standard; Y = Polyvinyl Chloride (PVC); Y = Polyvinyl Chloride (PVC); RM = Round Stranded Conductor, IEC 60228 Class 2.

2 coding systems recognise this code

**Standards behind these values:**

- IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
- IEC 60228:2023 (edition 4.0): Conductors of insulated cables

## DIN VDE 0271/0276 power cables (Germany)

| Symbol | Meaning |
|---|---|
| `N` | VDE Standard |
| `Y` | Polyvinyl Chloride (PVC) |
| `Y` | Polyvinyl Chloride (PVC) |
| `RM` | Round Stranded Conductor, IEC 60228 Class 2 |

[How to read a DIN VDE 0271/0276 power cables (Germany) cable code](https://thecablecode.com/guides/din-vde-0271-0276)

## DIN VDE 0250 cords, control and special cables (Germany)

| Symbol | Meaning |
|---|---|
| `N` | VDE Standard |
| `Y` | Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General |
| `Y` | Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General |
| `RM` | Round Stranded Conductor, IEC 60228 Class 2 |

[How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code](https://thecablecode.com/guides/old-vde-0250)

## NYY-RM: equivalents in other countries

Shown for 3x16 0.6/1 kV. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.

| Country | Standard | Name in that country | Verdict | Differences |
|---|---|---|---|---|
| International (IEC) | IEC 60502 | [Cu/PVC/PVC](https://thecablecode.com/c/CU/PVC/PVC) 3x16 0,6/1 kV (to IEC 60502-1) | **Equivalent** | every value the same |
| India | IS 1554 (Part 1) | [YY](https://thecablecode.com/c/YY) 3x16 1100 V (the code letters of IS 1554 (Part 1):1988 cl. 17.3) | **Close** | rated 0.635/1.1 kV (same Um 1.2 kV); Inner covering / bedding 1 → 0.3 mm; Overall diameter 20.47 → 19.07 mm |

Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.

- [NYY-RM cable: meaning, layers and 3D view](https://thecablecode.com/c/NYY-RM)
- [Design NYY-RM in the cable designer: layers, diameter and weight](https://thecablecode.com/design/NYY-RM)
- [More DIN VDE 0271/0276 power cables (Germany) designations](https://thecablecode.com/standards/din-vde-0271-0276)

## Related cables

- [NYY](https://thecablecode.com/c/NYY)
- [NYY-J](https://thecablecode.com/c/NYY-J)
- [NYY-O](https://thecablecode.com/c/NYY-O)
- [nyy 4x240](https://thecablecode.com/c/nyy%204x240)