title: "NXH cable: meaning, layers and 3D view"
code: "NXH"
url: https://thecablecode.com/c/NXH
language: en
---

# NXH

**NXH** is a [DIN VDE 0250 cords, control and special cables (Germany)](https://thecablecode.com/standards/old-vde-0250) cable designation: N = VDE Standard; X = Cross Linked Thermoplastics; H = Halogen-Free Compound (Insulation Or Sheath).

6 coding systems recognise this code

**Standards behind these values:**

- IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
- IEC 60228:2023 (edition 4.0): Conductors of insulated cables

## DIN VDE 0250 cords, control and special cables (Germany)

| Symbol | Meaning |
|---|---|
| `N` | VDE Standard |
| `X` | Cross Linked Thermoplastics |
| `H` | Halogen-Free Compound (Insulation Or Sheath) |

[How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code](https://thecablecode.com/guides/old-vde-0250)

## China (GB / JB/T / MT cable model codes)

| Symbol | Meaning |
|---|---|
| `N` | Nylon Jacket |
| `X` | Natural Or Styrene-Butadiene Rubber |
| `H` | Rubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables |

[How to read a China (GB / JB/T / MT cable model codes) cable code](https://thecablecode.com/guides/china)

## NEC Article 310 (US building wire, NFPA 70)

| Symbol | Meaning |
|---|---|
| `N` | Nylon Jacket |
| `X` | Cross-Linked Polymer Insulation |
| `H` | 75°C Insulation |

[How to read a NEC Article 310 (US building wire, NFPA 70) cable code](https://thecablecode.com/guides/nec-310)

## NEC Article 402 (US fixture wires, NFPA 70)

| Symbol | Meaning |
|---|---|
| `N` | Nylon Jacket |
| `X` | Cross-Linked Polyolefin Insulation |
| `H` | 75°C Heat-Resistant Insulation (After R Or FF); ECTFE Insulation (First Letter, HF / HFF) |

[How to read a NEC Article 402 (US fixture wires, NFPA 70) cable code](https://thecablecode.com/guides/nec-402)

## ZN-TF-500 (Poland, MV cables)

| Symbol | Meaning |
|---|---|
| `N` | Low Smoke Zero Halogen Compound |
| `X` | Polyethylene (PE) Sheath |
| `H` | Cable With Radial Field (Screened Cores, Medium Voltage) |

[How to read a ZN-TF-500 (Poland, MV cables) cable code](https://thecablecode.com/guides/zn-tf-500)

## Swiss cable codes (ASE/SEV wire codes and power cable codes)

| Symbol | Meaning |
|---|---|
| `N` | Halogen-Free Thermoplastic Sheath (PE Only) |
| `X` | Cross-Linked Polyethylene (XLPE) |
| `H` | Cable With Radial Electric Field (Höchstädter Type) |

[How to read a Swiss cable codes (ASE/SEV wire codes and power cable codes) cable code](https://thecablecode.com/guides/swiss)

- [NXH cable: meaning, layers and 3D view](https://thecablecode.com/c/NXH)
- [Design NXH in the cable designer: layers, diameter and weight](https://thecablecode.com/design/NXH)
- [More DIN VDE 0250 cords, control and special cables (Germany) designations](https://thecablecode.com/standards/old-vde-0250)

## Related cables

- [N2XH](https://thecablecode.com/c/N2XH)
- [NHXH](https://thecablecode.com/c/NHXH)
- [NXMH](https://thecablecode.com/c/NXMH)
- [XH](https://thecablecode.com/c/XH)
- [NX](https://thecablecode.com/c/NX)