title: "KVVR cable: meaning, layers and 3D view"
code: "KVVR"
url: https://thecablecode.com/c/KVVR
language: en
---

# KVVR

**KVVR** is a [China (GB / JB/T / MT cable model codes)](https://thecablecode.com/standards/china) cable designation: K = Control Cable; V = Polyvinyl Chloride (PVC); V = Polyvinyl Chloride (PVC); R = Flexible Cable.

2 coding systems recognise this code

**Standards behind these values:**

- IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
- IEC 60228:2023 (edition 4.0): Conductors of insulated cables

## China (GB / JB/T / MT cable model codes)

| Symbol | Meaning |
|---|---|
| `K` | Control Cable |
| `V` | Polyvinyl Chloride (PVC) |
| `V` | Polyvinyl Chloride (PVC) |
| `R` | Flexible Cable |

[How to read a China (GB / JB/T / MT cable model codes) cable code](https://thecablecode.com/guides/china)

## Norwegian type designation (NEK 606 offshore and Norwegian land cables)

| Symbol | Meaning |
|---|---|
| `K` | Paper |
| `V` | Screen (Draka key: aluminium screen; Nexans key: screen, optionally with PVC) |
| `V` | Double Wire Armour (Two Layers) |
| `R` | Ethylene Propylene Rubber (EPR) |

[How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code](https://thecablecode.com/guides/nek-606)

## KVVR: equivalents in other countries

Shown for 4x1.5 450/750 V. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.

| Country | Standard | Name in that country | Verdict | Differences |
|---|---|---|---|---|
| India | IS 694 | [FR](https://thecablecode.com/c/FR) FLEXIBLE 4x1,5 1100 V | **Close** | rated higher: 1100 V (this cable 450/750 V); Insulation 0.7 → 0.6 mm; Sheath 1.2 → 1 mm; Overall diameter 9.51 → 8.63 mm |

No equivalent in: EN 50525-2-11 (rated lower: 300/500 V (this cable 450/750 V)); EN 50525-2-51 (rated lower: 300/500 V (this cable 450/750 V)); DIN VDE 0250-405 (rated lower: 300/500 V (this cable 450/750 V)).

Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.

- [KVVR cable: meaning, layers and 3D view](https://thecablecode.com/c/KVVR)
- [Design KVVR in the cable designer: layers, diameter and weight](https://thecablecode.com/design/KVVR)
- [More China (GB / JB/T / MT cable model codes) designations](https://thecablecode.com/standards/china)

## Related cables

- [WDZC-KVVR](https://thecablecode.com/c/WDZC-KVVR)
- [YVV-R](https://thecablecode.com/c/YVV-R)
- [KVV](https://thecablecode.com/c/KVV)
- [VVR](https://thecablecode.com/c/VVR)