title: "EKK cable: meaning, layers and 3D view"
code: "EKK"
url: https://thecablecode.com/c/EKK
language: en
---

# EKK

**EKK** is a [SS 424 17 01 (Sweden)](https://thecablecode.com/standards/ss-424-17-01) cable designation: E = Copper Conductor - Single-Wire, Class 1; K = Polyvinyl Chloride (PVC); K = Polyvinyl Chloride (PVC).

3 coding systems recognise this code

**Standards behind these values:**

- IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
- IEC 60228:2023 (edition 4.0): Conductors of insulated cables

## SS 424 17 01 (Sweden)

| Symbol | Meaning |
|---|---|
| `E` | Copper Conductor - Single-Wire, Class 1 |
| `K` | Polyvinyl Chloride (PVC) |
| `K` | Polyvinyl Chloride (PVC) |

[How to read a SS 424 17 01 (Sweden) cable code](https://thecablecode.com/guides/ss-424-17-01)

## DIN VDE 0250 cords, control and special cables (Germany)

| Symbol | Meaning |
|---|---|
| `E` | Copper Drain / Earth Wire |
| `K` | Cold Resistant |
| `K` | Cold Resistant |

[How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code](https://thecablecode.com/guides/old-vde-0250)

## NEN 3207 / KEMA (Netherlands)

| Symbol | Meaning |
|---|---|
| `E` | Polyethylene (PE) |
| `KK` | Copper Sheathed Cable |

[How to read a NEN 3207 / KEMA (Netherlands) cable code](https://thecablecode.com/guides/kema)

## EKK: equivalents in other countries

Shown for 3x95 0.6/1 kV. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.

| Country | Standard | Name in that country | Verdict | Differences |
|---|---|---|---|---|
| Germany | HD 603 3-G (DIN VDE 0276-603) | [NYY](https://thecablecode.com/c/NYY) 3x95 RM 0,6/1 kV | **Equivalent** | every value the same |
| India | IS 1554 (Part 1) | [YY](https://thecablecode.com/c/YY) 3x95 1100 V (the code letters of IS 1554 (Part 1):1988 cl. 17.3) | **Close** | rated 0.635/1.1 kV (same Um 1.2 kV); routine voltage test 3 kV a.c., 5 min (this cable 3.5 kV; IS 1554 (Part 1) cl. 16.2, IS 7098 (Part 1) cl. 17.2.1, IEC 60502-1 Table 11); Inner covering / bedding 1.2 → 0.4 mm; Sheath 2.1 → 2.2 mm; this cable as built misses 1 of its rules |

Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.

- [EKK cable: meaning, layers and 3D view](https://thecablecode.com/c/EKK)
- [Design EKK in the cable designer: layers, diameter and weight](https://thecablecode.com/design/EKK)
- [More SS 424 17 01 (Sweden) designations](https://thecablecode.com/standards/ss-424-17-01)

## Related cables

- [EKK 3G1,5 Vit](https://thecablecode.com/c/EKK%203G1%2C5%20Vit)
- [EKRK](https://thecablecode.com/c/EKRK)